Paper
10 May 2011 Improvement of energy efficiency: the use of thermography and air-tightness test in verification of thermal performance of school buildings
Author Affiliations +
Abstract
The improvement of energy efficiency is the key issue after the energy performance of buildings directive came into the force in European Union countries. The city of Kuopio participate a project, in which different tools will be used, generated and tested to improve the energy efficiency of public buildings. In this project there are 2 schools, the other consuming much more heating energy than the other same type of school. In this paper the results of the thermography in normal conditions and under 50 Pa pressure drop will be presented; as well as the results of remote controlled air tightness test of the buildings. Thermography combined with air tightness test showed clearly the reasons of specific consumption differences of heating energy - also in the other hand, the measurements showed the problems in the performance of ventilation system. Thermography, air tightness test and other supporting measurements can be used together to solve energy loss problems - if these measurements will be carried out by proper way.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Timo Kauppinen and Sami Siikanen "Improvement of energy efficiency: the use of thermography and air-tightness test in verification of thermal performance of school buildings", Proc. SPIE 8013, Thermosense: Thermal Infrared Applications XXXIII, 801309 (10 May 2011); https://doi.org/10.1117/12.884513
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Buildings

Thermography

Protactinium

Energy efficiency

Fluctuations and noise

Temperature metrology

Bridges

Back to Top