You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
8 June 2011A reconstruction method for linear sensor microscopy based on improvement of lateral resolution isotropy
The aim of this work is to obtain improved sectioning ability in our slit-scanning microscope. The experimental setup is
based on a linear sensor and different illumination modes were evaluated. MTF measurements from USAF target images
showed the great benefit of using slit illumination in comparison to widefield. Experimental determination of Strehl
ratios of 0.62 and 0.96 for wide-field and slit-illumination configurations, respectively, is depicted. Also MTF
degradation with defocus is fairly established as stated by Strehl ratio decrease from 0.68 to 0.59 in 2 μm defocus using
widefield configuration. Experimental measurement of axial response showed good accordance to numerically simulated
curves modeled for the same parameters as the experimental setup. Linear sensor microscopy shows its advantage in
comparison to simple slit microscopy particularly for slit illumination. Imaging for details running in sensor direction is
accomplished for parallel illumination and detection slits as well as effective axial response for right-angled slits. These
results indicate that linear sensor microscopy should be able to surpass lateral resolution asymmetry of slit microscopy.
Preliminary results from tests to develop a reconstruction method that combine algorithms to improve lateral resolution
isotropy of 2D images and those to build 3D images will be presented.
M. P. Macedo andC.M.B.A. Correia
"A reconstruction method for linear sensor microscopy based on improvement of lateral resolution isotropy", Proc. SPIE 8086, Advanced Microscopy Techniques II, 80861J (8 June 2011); https://doi.org/10.1117/12.889962
The alert did not successfully save. Please try again later.
M. P. Macedo, C.M.B.A. Correia, "A reconstruction method for linear sensor microscopy based on improvement of lateral resolution isotropy," Proc. SPIE 8086, Advanced Microscopy Techniques II, 80861J (8 June 2011); https://doi.org/10.1117/12.889962