You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
6 October 2011Adjustable grazing incidence x-ray optics: measurement of actuator influence functions and comparison with modeling
The present generation of X-ray telescopes emphasizes either high image quality (e.g. Chandra with sub-arc
second resolution) or large effective area (e.g. XMM-Newton), while future observatories under consideration
(e.g. Athena, AXSIO) aim to greatly enhance the effective area, while maintaining moderate (~10 arc-seconds)
image quality. To go beyond the limits of present and planned missions, the use of thin adjustable optics for
the control of low-order figure error is needed to obtain the high image quality of precisely figured mirrors along
with the large effective area of thin mirrors. The adjustable mirror prototypes under study at Smithsonian
Astrophysical Observatory are based on two different principles and designs: 1) thin film lead-zirconate-titanate
(PZT) piezoelectric actuators directly deposited on the mirror back surface, with the strain direction parallel
to the glass surface (for sub-arc-second angular resolution and large effective area), and 2) conventional leadmagnesium-
niobate (PMN) electrostrictive actuators with their strain direction perpendicular to the mirror
surface (for 3-5 arc second resolution and moderate effective area). We have built and operated flat test mirrors
of these adjustable optics. We present the comparison between theoretical influence functions as obtained by
finite element analysis and the measured influence functions obtained from the two test configurations.
The alert did not successfully save. Please try again later.
Vincenzo Cotroneo, William N. Davis, Paul B. Reid, Daniel A. Schwartz, Susan Trolier-McKinstry, Rudeger H. T. Wilke, "Adjustable grazing incidence x-ray optics: measurement of actuator influence functions and comparison with modeling," Proc. SPIE 8147, Optics for EUV, X-Ray, and Gamma-Ray Astronomy V, 81471R (6 October 2011); https://doi.org/10.1117/12.895475