A continuous emission monitoring system (CEMS) using hot wet extractive method based on differential optical absorption spectroscopy (DOAS) is designed. The developed system is applied to retrieving the concentration of SO2 and NOx in flue gas on-site. The flue gas is carried along a heated sample line into the sample pool at a constant temperature above the dew point. In this case, the adverse impact of water vapor on measurement accuracy is reduced greatly, and the on-line calibration is implemented. And then the flue gas is discharged from the sample pool after the measuring process is complete. The on-site applicability of the system is enhanced by using Programmable Logic Controller (PLC) to control each valve in the system during the measuring and on-line calibration process. The concentration retrieving method used in the system is based on the partial least squares (PLS) regression nonlinear method. The relationship between the known concentration and the differential absorption feature gathered by the PLS nonlinear method can be figured out after the on-line calibration process. Then the concentration measurement of SO2 and NOx can be easily implemented according to the definite relationship. The concentration retrieving method can identify the information and noise effectively, which improves the measuring accuracy of the system. SO2 with four different concentrations are measured by the system under laboratory conditions. The results proved that the full-scale error of this system is less than 2%FS.
© (2011) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Bo Sun, Chi Zhang, and Changku Sun "CEMS using hot wet extractive method based on DOAS", Proc. SPIE 8201, 2011 International Conference on Optical Instruments and Technology: Optoelectronic Measurement Technology and Systems, 82011E (30 November 2011); https://doi.org/10.1117/12.904792
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Absorption

Photonic integrated circuits

Nitrous oxide

Control systems

Sensors

Absorption spectroscopy

Back to Top