Abstract
Regarding to the mistakes that optoelectronic devices such as CCD focal plane arrays devices are often placed on the exit port plane of integrating sphere source to perform calibration, the output irradiance uniformity of integrating sphere source is analyzed, the basis which rational using the integrating sphere source to calibrate the optoelectronic devices is obtained. Two theoretical output irradiance uniformity models based on numerical analysis method and Monte Carlo method are developed respectively. The models consider two fundamental situations of integrating sphere sources, namely (1) ideal lambertian source and (2) non-ideal lambertian source. The distribution regularity of irradiance uniformity was generalized by contrast of the theoretical data obtained by the models and the measured data obtained by two different actual integrating sphere sources. The results show that when (1) the diameter of optoelectronic device is less than half diameter of the sphere exit port, and (2)the ratio of the distance from device to exit port and the exit port diameter are between 3 and 5, a 99% better output irradiance uniformity can be obtained. The results provide a practical guide to ensure the accuracy of the calibration exercise of optoelectronic devices.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yingwei He, Ping Li, Houping Wu, Cheng Li, Limin Xiong, Haifeng Meng, Dingpu Liu, Jieyu Zhang, and Junchao Zhang "Analysis of the output irradiance uniformity of integrating sphere source", Proc. SPIE 8417, 6th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, 841729 (15 October 2012); https://doi.org/10.1117/12.978690
PROCEEDINGS
10 PAGES


SHARE
Advertisement
Advertisement
RELATED CONTENT

Polar synthetic imaging
Proceedings of SPIE (May 31 2013)
Towards post launch validation of GOES R ABI SI traceability...
Proceedings of SPIE (September 19 2016)
On-orbit radiance correction for ocean-color CCD imager
Proceedings of SPIE (August 18 1998)
Summary of the operational land imager focal plane array for...
Proceedings of SPIE (September 16 2011)
Relative performance studies for focal-plane arrays
Proceedings of SPIE (September 01 1991)

Back to Top