You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
29 June 2012Closed loop registration control (RegC) using PROVE as the data source for the RegC process
At sub 4X nm nodes in memory and sub 3X nodes in logic devices mask registration (Reg) is becoming a
significant yield limiting factor. This is especially true for Double Patterning Technologies (DPT) where
mask to mask overlay on the wafer is heavily influenced by mask registration error. Getting advanced mask
registration into specification is a challenge for all mask shops as the tight registration specs are driven by
tight wafer overlay specs.
The first step in meeting the registration spec challenge in the mask shop is to be able to measure registration
with the required specifications. With PROVE® Carl Zeiss SMS has recently introduced into the market a
new registration and overlay metrology system which utilizes 193nm illumination for high resolution and a
six axes controlled stage. The second step in meeting the registration spec challenge is to actively correct for
intrinsic registration errors on the mask. For this Carl Zeiss SMS has developed the RegC® tool. The RegC®
tool is based on writing strain zones with the help of an ultrashort pulse laser in the bulk of the mask. The
strain zones induce deformations in the mask which practically push the misplaced features to a new location
that after removing scale and orthogonality (S/O) correctable errors reflects a smaller residual registration
error.
By combining the RegC® tool with data generated by PROVE® it is possible to close the loop on the
registration control process in the mask shop without wafer print or mask re-write.
In this paper we report the demonstration results of a closed loop process between PROVE® and the RegC®
tools.
The alert did not successfully save. Please try again later.
Erez Graitzer, Avi Cohen, Vladimir Dmitriev, Itamar Balla, Dan Avizemer, Dirk Beyer, Klaus Boehm, Wolfgang Degel, "Closed loop registration control (RegC) using PROVE as the data source for the RegC process," Proc. SPIE 8441, Photomask and Next-Generation Lithography Mask Technology XIX, 84410A (29 June 2012); https://doi.org/10.1117/12.976632