Paper
25 September 2012 Modelling charge transfer in a radiation damaged charge coupled device for Euclid
Author Affiliations +
Abstract
As electrons are transferred through a radiation damaged Charge Coupled Device (CCD), they may encounter traps in the silicon in which they will be captured and subsequently released. This capture and release of electrons can lead to a 'smearing' of the image. The dynamics of the trapping process can be described through the use of Shockley-Read-Hall theory, in which exponential time constants are used to determine the probability of capture and release. If subjected to a hostile radiation environment, such as in space where the dominant charged particle is the proton, these incident protons can cause displacement damage within the CCD and lead to the formation of stable trap sites. As the trap density increases, the trapping and release of signal electrons can have a major impact on the Charge Transfer Efficiency (CTE) to the detriment of device performance. As the science goals for missions become ever more demanding, such as those for the ESA Euclid and Gaia missions, the problem of radiation damage must be overcome. In order to gain a deeper understanding of the trapping process and the impact on device performance, a Monte Carlo simulation has been developed to model the transfer of charge in a radiation damaged CCD. This study investigates the various difficulties encountered when developing such a model: the incorporation of appropriate clocking mechanisms, the use of suitable trap parameters and their degeneracy, and the development of methods to model the charge storage geometry within a pixel through the use of three-dimensional Silvaco simulations.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
David J. Hall, Andrew Holland, Neil Murray, Jason Gow, and Andrew Clarke "Modelling charge transfer in a radiation damaged charge coupled device for Euclid", Proc. SPIE 8453, High Energy, Optical, and Infrared Detectors for Astronomy V, 845315 (25 September 2012); https://doi.org/10.1117/12.925394
Lens.org Logo
CITATIONS
Cited by 14 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

Charge-coupled devices

Electrons

3D modeling

Modeling

Data modeling

Electrodes

RELATED CONTENT

Performance of the XMM EPIC MOS CCD detectors
Proceedings of SPIE (November 10 1998)
Modelling radiation damage to ESA's Gaia satellite CCDs
Proceedings of SPIE (July 22 2008)
3D modeling of Cd(Zn)Te detectors for the Simbol X space...
Proceedings of SPIE (September 29 2004)
Gaia astrometric CCDs and focal plane
Proceedings of SPIE (August 25 2005)

Back to Top