6 March 2013 Experimental study of optimal energy weighting in energy-resolved CT using a CZT detector
Franco Rupcich, Taly Gilat-Schmidt
Author Affiliations +
Proceedings Volume 8668, Medical Imaging 2013: Physics of Medical Imaging; 86681X (2013) https://doi.org/10.1117/12.2008439
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Recent advances in energy-resolved CT can potentially improve contrast-to-noise ratio (CNR), which could subsequently reduce dose in conventional and dedicated breast CT. Two methods have been proposed for optimal energy weighting: weighting the energy- bin data prior to log normalization (projection- based weighting) and weighting the energy-bin data after log normalization (image-based weighting). Previous studies suggested that optimal projection-based and image-based energy weighting provide similar CNR improvements for energy­ resolved CT compared to photon-counting or conventional energy-integrating CT. This study experimentally investigated the improvement in CNR of projection-based and image-based weighted images relative to photon­ counting for six different energy-bin combinations using a bench top system with a CZT detector. The results showed CNR values ranged between 0.85 and 1.01 for the projection- based weighted images and between 0.91 and 1.43 for the image- based weighted images, relative to the CNR for the photon-counting image. The range of CNR values demonstrates the effects of energy-bin selection on CNR for a particular energy weighting scheme. The non-ideal spectral response of the CZT detector caused spectral tailing, which appears to generally reduce the CNR for the projection-based weighted images. Image-based weighting increased CNR in five of the six bin combinations despite the non-ideal spectral effects.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Franco Rupcich and Taly Gilat-Schmidt "Experimental study of optimal energy weighting in energy-resolved CT using a CZT detector", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 86681X (6 March 2013); https://doi.org/10.1117/12.2008439
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Photons

Sensors

Computed tomography

Breast

Electronic test equipment

Photon counting

Calcium

Back to Top