13 March 2013 3D registration of histology and ultrasound data for validation of prostate cancer imaging
Stefan G. Schalk, Tamerlan A. Saidov, Hessel Wijkstra, Massimo Mischi
Author Affiliations +
Proceedings Volume 8669, Medical Imaging 2013: Image Processing; 86692T (2013) https://doi.org/10.1117/12.2001842
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Several ultrasound (US) prostate cancer localization methods are emerging, opening opportunities for targeted biopsies and focal therapy. However, before any of these methods, like elastography or contrast-enhanced US, can be introduced into clinical practice, accurate validation is required. The current gold standard for validation is histological assessment of the prostate after radical prostatectomy. Therefore, a 3D registration of histological and US data is required. This task is complicated by misalignment between histology slices and ultrasound imaging planes, pressure caused by the adopted transrectal US probe, and deformation and volume change during fixation in formalin solution. In this work, we introduce a dedicated 3D algorithm, automatically registering histology and ultrasound data. Because there is no information available between histology slices, and internal landmarks are not consistently present in US images, registration is based on outer-contours shape only. A 3D surface model of the prostate in constructed, based on manually outlined contours in a transrectal sweep video and a longitudinal image. Also, a similar model is constructed from the histology slices, including cancerous areas marked by a pathologist. Registration of the models is then performed in three steps: affine registration, elastic surface registration, and internal registration. In-vitro validation of the algorithm was performed by inserting rubber wires into four prostate mimicking phantoms and applying probe pressure. The resulting registration accuracy was 1.6 mm, which is considerably smaller than the histology slicing resolution of 4 mm.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Stefan G. Schalk, Tamerlan A. Saidov, Hessel Wijkstra, and Massimo Mischi "3D registration of histology and ultrasound data for validation of prostate cancer imaging", Proc. SPIE 8669, Medical Imaging 2013: Image Processing, 86692T (13 March 2013); https://doi.org/10.1117/12.2001842
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Prostate

Image registration

3D modeling

Ultrasonography

Principal component analysis

In vitro testing

Tissues

Back to Top