You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
28 March 2013Analysis of individual variability and habituation in stereoscopic radiography
In our previous stereoscopic image for medical use research, we reported that observers found it is easier to identify target objects in stereoscopic images than in two dimensional images, however, we found that mental and visual fatigue levels are equivalent in viewing the stereoscopic and the two dimensional images. We reported that a number of users dislike the sensations accompanying stereoscopic vision. Hence, we studied personal variation of stereoscopic visibility and the training effect for the stereoscopic visibility in this research. Simulated images, in which prepared calcifications were arranged at parallactic angles between ±2° to ±15° at object heights from 40 to 80mm, were displayed on a stereoscopic 3D display. Seven observers were selected to judge the achievement of stereoscopic vision (stereopsis) and their visibility was determined. The observers were asked to point the stereoscopic cursor of the 3D mammography viewer at the simulated calcifications and the accuracy rates were determined. Subsequently, re-examination was implemented after 3D visual training for 15 to 20 minutes per day for two weeks, and the visibility and accuracy rates were measured again. We found individual differences in the parallactic angles at which stereopsis was realized. Moreover, the parallactic angles of stereopsis widened through training and the average visibility improved from 69% to 84% as the result of training. Furthermore, the average accuracy rates improved from 53% to 60% the accuracy of depth commands improved. This suggests that observers who are weak in stereoscopic vision can be trained to be better at stereoscopic viewing.
The alert did not successfully save. Please try again later.
Yasuko Y. Unno, Takao Kuwabara, Robert A. Uzenoff, Nobutaka Natsui, Kazuo Ishikawa, "Analysis of individual variability and habituation in stereoscopic radiography," Proc. SPIE 8673, Medical Imaging 2013: Image Perception, Observer Performance, and Technology Assessment, 86730X (28 March 2013); https://doi.org/10.1117/12.2006650