You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
28 March 2013A study of the feasibility of using slabbing to reduce tomosynthesis review time
This study aimed to investigate whether decreasing the amount of slices in breast tomosynthesis (BT) image volumes reduce reading time. BT slices were combined into so-called slabs, by reconstructing thin slices and merging them into thicker slabs. Sets of slabs where created from 35 clinical BT volumes with malignant or benignant findings and from 50 BT volumes drawn from screening sets (without any prior review). The image sets were reviewed in two separate sessions while the review time was recorded. A total of five experienced radiologists were employed for the image review. Additionally a VGA study was performed to compare slabbed images with the originals in order to ensure that the image quality was not significantly degraded. One set of 27 pathological cases (13 masses and 14 microcalcification clusters) and one of 22 subtle lesions that had been missed on digital mammography but detected on BT were presented to an experienced radiologist and 2 medical physicists who rated the quality of the slabbed versions relative to the originals. The study could find no significant degradation in image quality when using 2 mm slabs instead of 1 mm slices. There was no significant decrease in reading time on clinical cases (P = .133), but on screening images there was a significant decrease of 7.7 ± 9.6 s from an average level of 32.2 ± 14.5 s (P < .0001). This suggests that increasing slab thickness can reduce the time radiologists spend studying normal images by 20%.
The alert did not successfully save. Please try again later.
Magnus Dustler, Martin Andersson, Daniel Förnvik, Pontus Timberg, Anders Tingberg, "A study of the feasibility of using slabbing to reduce tomosynthesis review time," Proc. SPIE 8673, Medical Imaging 2013: Image Perception, Observer Performance, and Technology Assessment, 86731L (28 March 2013); https://doi.org/10.1117/12.2006987