You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
18 February 2014Efficacy of multiple exposure with low level He-Ne laser dose on acute wound healing: a pre-clinical study
Investigations on the use of Low Level Laser Therapy (LLLT) for wound healing especially with the red laser light have
demonstrated its pro-healing potential on a variety of pre-clinical and surgical wounds. However, until now, in LLLT the
effect of multiple exposure of low dose laser irradiation on acute wound healing on well-designed pre-clinical model is
not much explored. The present study aimed to investigate the effect of multiple exposure of low dose Helium Neon
laser on healing progression of full thickness excision wounds in Swiss albino mice. Further, the efficacy of the multiple
exposure of low dose laser irradiation was compared with the single exposure of optimum dose. Full thickness excision
wounds (circular) of 15 mm diameter were created, and subsequently illuminated with the multiple exposures (1, 2, 3, 4
and 5 exposure/ week until healing) of He-Ne (632.8 nm, 4.02 mWcm-2) laser at 0.5 Jcm-2 along with single exposure of
optimum laser dose (2 J/cm-2) and un-illuminated controls. Classical biophysical parameters such as contraction kinetics,
area under the curve and the mean healing time were documented as the assessment parameters to examine the efficacy
of multiple exposures with low level laser dose. Experimental findings substantiated that either single or multiple
exposures of 0.5 J/cm2 failed to produce any detectable alterations on wound contraction, area under the curve and mean
healing time compared to single exposure of optimum dose (2 Jcm-2) and un-illuminated controls. Single exposure of optimum, laser dose was found to be ideal for acute wound healing.
The alert did not successfully save. Please try again later.
Vijendra Prabhu, Bola Sadashiva Satish Rao, Krishna Kishore Mahato, "Efficacy of multiple exposure with low level He-Ne laser dose on acute wound healing: a pre-clinical study," Proc. SPIE 8932, Mechanisms for Low-Light Therapy IX, 89320T (18 February 2014); https://doi.org/10.1117/12.2041084