Paper
6 March 2014 Comprehensive evaluation of latest 2D/3D monitors and comparison to a custom-built 3D mirror-based display in laparoscopic surgery
Dirk Wilhelm, Silvano Reiser, Nils Kohn, Michael Witte, Ulrich Leiner, Lothar Mühlbach, Detlef Ruschin, Wolfgang Reiner, Hubertus Feussner
Author Affiliations +
Proceedings Volume 9011, Stereoscopic Displays and Applications XXV; 90110H (2014) https://doi.org/10.1117/12.2040040
Event: IS&T/SPIE Electronic Imaging, 2014, San Francisco, California, United States
Abstract
Though theoretically superior, 3D video systems did not yet achieve a breakthrough in laparoscopic surgery. Furthermore, visual alterations, such as eye strain, diplopia and blur have been associated with the use of stereoscopic systems. Advancements in display and endoscope technology motivated a re-evaluation of such findings. A randomized study on 48 test subjects was conducted to investigate whether surgeons can benefit from using most current 3D visualization systems. Three different 3D systems, a glasses-based 3D monitor, an autostereoscopic display and a mirror-based theoretically ideal 3D display were compared to a state-of-the-art 2D HD system. The test subjects split into a novice and an expert surgeon group, which high experience in laparoscopic procedures. Each of them had to conduct a well comparable laparoscopic suturing task. Multiple performance parameters like task completion time and the precision of stitching were measured and compared. Electromagnetic tracking provided information on the instruments path length, movement velocity and economy. The NASA task load index was used to assess the mental work load. Subjective ratings were added to assess usability, comfort and image quality of each display. Almost all performance parameters were superior for the 3D glasses-based display as compared to the 2D and the autostereoscopic one, but were often significantly exceeded by the mirror-based 3D display. Subjects performed the task at average 20% faster and with a higher precision. Work-load parameters did not show significant differences. Experienced and non-experienced laparoscopists profited equally from 3D. The 3D mirror system gave clear evidence for additional potential of 3D visualization systems with higher resolution and motion parallax presentation.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dirk Wilhelm, Silvano Reiser, Nils Kohn, Michael Witte, Ulrich Leiner, Lothar Mühlbach, Detlef Ruschin, Wolfgang Reiner, and Hubertus Feussner "Comprehensive evaluation of latest 2D/3D monitors and comparison to a custom-built 3D mirror-based display in laparoscopic surgery", Proc. SPIE 9011, Stereoscopic Displays and Applications XXV, 90110H (6 March 2014); https://doi.org/10.1117/12.2040040
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
3D displays

Laparoscopy

Surgery

Visualization

Imaging systems

Mirrors

3D visualizations

RELATED CONTENT


Back to Top