You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
18 September 2014Laboratory radiometric calibration for the convex grating imaging spectrometer
The radiometric calibration of imaging spectrometer plays an import role for scientific application of spectral data. The radiometric calibration accuracy is influenced by many factors, such as the stability and uniformity of light source, the transfer precision of radiation standard and so on. But the deviation from the linear response mode and the polarization effect of the imaging spectrometer are always neglected. In this paper, the linear radiometric calibration model is constructed and the radiometric linear response capacity is test by adjusting electric gain, exposure time and radiance level. The linear polarizer and the sine function fitting algorithm are utilized to measure polarization effect. The integrating sphere calibration system is constructed in our Lab and its spectral radiance is calibrated by a well-characterized and extremely stable NIST traceable transfer spectroradiometer. Our manufactured convex grating imaging spectrometer is relative and absolute calibrated based on the integrating sphere calibration system. The relative radiometric calibration data is used to remove or reduce the radiometric response non-uniformity every pixel of imaging spectrometer while the absolute radiometric calibration is used to construct the relationship between the physical radiant of the scene and the digital number of the image. The calibration coefficients are acquired at ten radiance levels. The diffraction noise in the images can be corrected by the calibration coefficients and the uniform radiance image can be got. The calibration result shows that our manufactured imaging spectrometer with convex grating has 3.0% degree of polarization and the uncertainties of the relative and absolute radiometric calibrations are 2.4% and 5.6% respectively.
Jiankang Zhou,Xinhua Chen,Yuheng Chen,Yiqun Ji, andWeimin Shen
"Laboratory radiometric calibration for the convex grating imaging spectrometer
", Proc. SPIE 9282, 7th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, 92822G (18 September 2014); https://doi.org/10.1117/12.2069732