Paper
22 August 2014 Real-time dosimeter targeted to nuclear applications
Alexandre Correia, Carla C. Rosa, Pedro M. P. Santos, António N. Falcão, Katharina Lorentz
Author Affiliations +
Proceedings Volume 9286, Second International Conference on Applications of Optics and Photonics; 92864R (2014) https://doi.org/10.1117/12.2063832
Event: Second International Conference on Applications of Optics and Photonics, 2014, Aveiro, Portugal
Abstract
An intrinsic fiber optic dosimeter (FOD) targeted to nuclear applications is presented. The proposed real-time dosimeter provides dose information based on the historic record over time of the effects of ionizing radiation on single- and multimode pure silica fibers, and also on PMMA plastic fibers. The effect of 60Co gamma irradiation on optical links based on silica and plastic fibers were assessed, considering thermal environment effects over a wide range of variation of the operating parameters. Cerenkov radiation and radiation-induced absorption effects were in focus. The corresponding distortion and spectral transmission degradation were evaluated over wide range of the operating parameters. Radiation induced attenuation (RIA) has shown a spectral band dependent behaviour up to 840 Gy dose levels. The performance of different fibers was assessed against the performance of non-irradiated fibers. From the measurements of dose rate and total dose imparted by ionizing radiation in the fibers we verified that fibers with radiation resistance issues showed wavelength-dependent radiation sensitivity increasing with dose rate. Upon evaluation of correlations between the total dose, the induced loss at various dose rates and different wavelengths, it was concluded that intrinsic fiber dosimeters can be used for dose rates in the range 4 - 28 Gy/min., typical of severe radiation environments.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Alexandre Correia, Carla C. Rosa, Pedro M. P. Santos, António N. Falcão, and Katharina Lorentz "Real-time dosimeter targeted to nuclear applications", Proc. SPIE 9286, Second International Conference on Applications of Optics and Photonics, 92864R (22 August 2014); https://doi.org/10.1117/12.2063832
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical fibers

Signal attenuation

Fiber optics

Ionizing radiation

Absorption

Polymethylmethacrylate

Radiation effects

RELATED CONTENT

Effect Of Ionizing Radiation On Fiber-Optic Waveguides
Proceedings of SPIE (January 22 1982)
Business Opportunities In Fibre Optics
Proceedings of SPIE (September 17 1987)
Reversible low-loss fiber optic hydrazine sensor
Proceedings of SPIE (April 24 2010)
Quality control of UV resistant fibers for 200 300 nm...
Proceedings of SPIE (February 19 2008)

Back to Top