Paper
2 March 2015 High-speed, digitally refocused retinal imaging with line-field parallel swept source OCT
Author Affiliations +
Abstract
MHz OCT allows mitigating undesired influence of motion artifacts during retinal assessment, but comes in state-of-the-art point scanning OCT at the price of increased system complexity. By changing the paradigm from scanning to parallel OCT for in vivo retinal imaging the three-dimensional (3D) acquisition time is reduced without a trade-off between speed, sensitivity and technological requirements. Furthermore, the intrinsic phase stability allows for applying digital refocusing methods increasing the in-focus imaging depth range. Line field parallel interferometric imaging (LPSI) is utilizing a commercially available swept source, a single-axis galvo-scanner and a line scan camera for recording 3D data with up to 1MHz A-scan rate. Besides line-focus illumination and parallel detection, we mitigate the necessity for high-speed sensor and laser technology by holographic full-range imaging, which allows for increasing the imaging speed by low sampling of the optical spectrum. High B-scan rates up to 1kHz further allow for implementation of lable-free optical angiography in 3D by calculating the inter B-scan speckle variance. We achieve a detection sensitivity of 93.5 (96.5) dB at an equivalent A-scan rate of 1 (0.6) MHz and present 3D in vivo retinal structural and functional imaging utilizing digital refocusing. Our results demonstrate for the first time competitive imaging sensitivity, resolution and speed with a parallel OCT modality. LPSI is in fact currently the fastest OCT device applied to retinal imaging and operating at a central wavelength window around 800 nm with a detection sensitivity of higher than 93.5 dB.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Daniel J. Fechtig, Abhishek Kumar, Laurin Ginner, Wolfgang Drexler, and Rainer A. Leitgeb "High-speed, digitally refocused retinal imaging with line-field parallel swept source OCT", Proc. SPIE 9312, Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine XIX, 931203 (2 March 2015); https://doi.org/10.1117/12.2081924
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications and 2 patents.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Optical coherence tomography

3D acquisition

Retinal scanning

3D image processing

In vivo imaging

Sensors

Interferometry

Back to Top