You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
18 March 2015Application of the fractal Perlin noise algorithm for the generation of simulated breast tissue
Software breast phantoms are increasingly seeing use in preclinical validation of breast image acquisition systems and image analysis methods. Phantom realism has been proven sufficient for numerous specific validation tasks. A challenge is the generation of suitably realistic small-scale breast structures that could further improve the quality of phantom images. Power law noise follows the noise power characteristics of breast tissue, but may not sufficiently represent certain (e.g., non-Gaussian) properties seen in clinical breast images. The purpose of this work was to investigate the utility of fractal Perlin noise in generating more realistic breast tissue through investigation of its power spectrum and visual characteristics. Perlin noise is an algorithm that creates smoothly varying random structures of an arbitrary frequency. Through the use of a technique known as fractal noise or fractional Brownian motion (fBm), octaves of noise with different frequency are combined to generate coherent noise with a broad frequency range. fBm is controlled by two parameters – lacunarity and persistence – related to the frequency and amplitude of successive octaves, respectively. Average noise power spectra were calculated and beta parameters estimated in sample volumes of fractal Perlin noise with different combinations of lacunarity and persistence. Certain combinations of parameters resulted in noise volumes with beta values between 2 and 3, corresponding to reported measurements in real breast tissue. Different combinations of parameters resulted in different visual appearances. In conclusion, Perlin noise offers a flexible tool for generating breast tissue with realistic properties.
The alert did not successfully save. Please try again later.
Magnus Dustler, Predrag Bakic, Hannie Petersson, Pontus Timberg, Anders Tingberg, Sophia Zackrisson, "Application of the fractal Perlin noise algorithm for the generation of simulated breast tissue," Proc. SPIE 9412, Medical Imaging 2015: Physics of Medical Imaging, 94123E (18 March 2015); https://doi.org/10.1117/12.2081856