18 March 2015 Prospective gated chest tomosynthesis using CNT X-ray source array
Jing Shan, Laurel Burk, Gongting Wu, Yueh Z. Lee M.D., Michael D. Heath, Xiaohui Wang, David Foos, Jianping Lu, Otto Zhou
Author Affiliations +
Abstract
Chest tomosynthesis is a low-dose 3-D imaging modality that has been shown to have comparable sensitivity as CT in detecting lung nodules and other lung pathologies. We have recently demonstrated the feasibility of stationary chest tomosynthesis (s-DCT) using a distributed CNT X-ray source array. The technology allows acquisition of tomographic projections without moving the X-ray source. The electronically controlled CNT x-ray source also enables physiologically gated imaging, which will minimize image blur due to the patient’s respiration motion. In this paper, we investigate the feasibility of prospective gated chest tomosynthesis using a bench-top s-DCT system with a CNT source array, a high- speed at panel detector and realistic patient respiratory signals captured using a pressure sensor. Tomosynthesis images of inflated pig lungs placed inside an anthropomorphic chest phantom were acquired at different respiration rate, with and without gating for image quality comparison. Metal beads of 2 mm diameter were placed on the pig lung for quantitative measure of the image quality. Without gating, the beads were blurred to 3:75 mm during a 3 s tomosynthesis acquisition. When gated to the end of the inhalation and exhalation phase the detected bead size reduced to 2:25 mm, much closer to the actual bead size. With gating the observed airway edges are sharper and there are more visible structural details in the lung. Our results demonstrated the feasibility of prospective gating in the s-DCT, which substantially reduces image blur associated with lung motion.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jing Shan, Laurel Burk, Gongting Wu, Yueh Z. Lee M.D., Michael D. Heath, Xiaohui Wang, David Foos, Jianping Lu, and Otto Zhou "Prospective gated chest tomosynthesis using CNT X-ray source array", Proc. SPIE 9412, Medical Imaging 2015: Physics of Medical Imaging, 941242 (18 March 2015); https://doi.org/10.1117/12.2081701
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Lung

X-ray sources

Chest

Sensors

Image quality

X-rays

Metals

Back to Top