You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
20 March 2015Robustness evaluation of a computer-aided detection system for pulmonary embolism (PE) in CTPA using independent test set from multiple institutions
We have developed a computer-aided detection (CAD) system for assisting radiologists in detection of pulmonary embolism (PE) in computed tomographic pulmonary angiographic (CTPA) images. The CAD system includes stages of pulmonary vessel segmentation, prescreening of PE candidates and false positive (FP) reduction to identify suspicious PEs. The system was trained with 59 CTPA PE cases collected retrospectively from our patient files (UM set) with IRB approval. Five feature groups containing 139 features that characterized the intensity texture, gradient, intensity homogeneity, shape, and topology of PE candidates were initially extracted. Stepwise feature selection guided by simplex optimization was used to select effective features for FP reduction. A linear discriminant analysis (LDA) classifier was formulated to differentiate true PEs from FPs. The purpose of this study is to evaluate the performance of our CAD system using an independent test set of CTPA cases. The test set consists of 50 PE cases from the PIOPED II data set collected by multiple institutions with access permission. A total of 537 PEs were manually marked by experienced thoracic radiologists as reference standard for the test set. The detection performance was evaluated by freeresponse receiver operating characteristic (FROC) analysis. The FP classifier obtained a test Az value of 0.847 and the FROC analysis indicated that the CAD system achieved an overall sensitivity of 80% at 8.6 FPs/case for the PIOPED test set.
The alert did not successfully save. Please try again later.
Chuan Zhou, Heang-Ping Chan, Aamer Chughtai, Jean W. Kuriakose, Ella A. Kazerooni M.D., Lubomir M. Hadjiiski, Jun Wei, Smita Patel, "Robustness evaluation of a computer-aided detection system for pulmonary embolism (PE) in CTPA using independent test set from multiple institutions," Proc. SPIE 9414, Medical Imaging 2015: Computer-Aided Diagnosis, 941408 (20 March 2015); https://doi.org/10.1117/12.2082015