You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
27 March 2015Investigation of eddy current examination on OD fatigue crack for steam generator tubes
The opening width of fatigue crack was very small, and conventional Bobbin
probe was very difficult to detect it in steam generator tubes. Different sizes of 8 fatigue cracks
were inspected using bobbin probe rotating probe. The analysis results showed that, bobbin
probe was not sensitive for fatigue crack even for small through wall crack mixed with denting
signal. On the other hand, the rotating probe was easily to detect all cracks. Finally, the OD
phase to depth curve for fatigue crack using rotating probe was established and the results
agreed very well with the true crack size.
The alert did not successfully save. Please try again later.
Yuying Kong, Boyuan Ding, Ming Li, Jinhong Liu, Huaidong Chen, Norbert G. Meyendorf, "Investigation of eddy current examination on OD fatigue crack for steam generator tubes," Proc. SPIE 9439, Smart Materials and Nondestructive Evaluation for Energy Systems 2015, 94390X (27 March 2015); https://doi.org/10.1117/12.2084713