Paper
5 May 2015 Investigating temperature effects on the spectral lines of blue laser diodes for monitoring NO2 gas pollution
Khaled Gasmi, Watheq Al-Basheer, Abdulaziz Aljalal
Author Affiliations +
Abstract
Temperature effects on the spectral lines of two Fabry-Perot GaN-based blue laser diodes obtained from Toptica and Roithner Laser Tech are experimentally investigated over the temperature range 5 °C to 60 °C in steps of 0.5 °C. A high resolution monochromator SPEX 1403 with a nominal resolution of 0.003 nm is used in this study. A detailed comparison on the number of modes, mode spacing, emission range and change of emission wavelength per degree Celsius will be presented in this paper. The results of this comparison are used to investigate the suitability of the employment of these laser diodes in open-path detection of NO2 gas pollution.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Khaled Gasmi, Watheq Al-Basheer, and Abdulaziz Aljalal "Investigating temperature effects on the spectral lines of blue laser diodes for monitoring NO2 gas pollution", Proc. SPIE 9506, Optical Sensors 2015, 950628 (5 May 2015); https://doi.org/10.1117/12.2179135
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Semiconductor lasers

Diodes

Monochromators

NOx

Pollution

Temperature metrology

CCD cameras