Paper
5 August 2015 Determination of glucose concentration based on pulsed laser induced photoacoustic technique and least square fitting algorithm
Zhong Ren, Guodong Liu, Zhen Huang
Author Affiliations +
Abstract
In this paper, a noninvasive glucose concentration monitoring setup based on the photoacoustic technique was established. In this setup, a 532nm pumped Q switched Nd: YAG tunable pulsed laser with repetition rate of 20Hz was used as the photoacoustic excitation light source, and a ultrasonic transducer with central response frequency of 9.55MHz was used as the detector of the photoacoustic signal of glucose. As the preliminary exploration of the blood glucose concentration, a series of in vitro photoacoustic monitoring of glucose aqueous solutions by using the established photoacoustic setup were performed. The photoacoustic peak-to-peak values of different concentrations of glucose aqueous solutions induced by the pulsed laser with output wavelength of 1300nm to 2300nm in interval of 10nm were obtained with the average times of 512. The differential spectral and the first order derivative spectral method were used to get the characteristic wavelengths. For the characteristic wavelengths of glucose, the least square fitting algorithm was used to establish the relationship between the glucose concentrations and photoacoustic peak-to-peak values. The characteristic wavelengths and the predicted concentrations of glucose solution were obtained. Experimental results demonstrated that the prediction effect of characteristic wavelengths of 1410nm and 1510nm were better than others, and this photoacoustic setup and analysis method had a certain potential value in the monitoring of the blood glucose concentration.
© (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Zhong Ren, Guodong Liu, and Zhen Huang "Determination of glucose concentration based on pulsed laser induced photoacoustic technique and least square fitting algorithm", Proc. SPIE 9619, 2015 International Conference on Optical Instruments and Technology: Optoelectronic Devices and Optical Signal Processing, 96190M (5 August 2015); https://doi.org/10.1117/12.2190601
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Glucose

Photoacoustic spectroscopy

Pulsed laser operation

Signal detection

Blood

Transducers

Ultrasonics

Back to Top