18 March 2016 Impact of region contouring variability on image-based focal therapy evaluation
Eli Gibson, Ian A. Donaldson, Taimur T. Shah, Yipeng Hu, Hashim U. Ahmed, Dean C. Barratt
Author Affiliations +
Abstract
Motivation: Focal therapy is an emerging low-morbidity treatment option for low-intermediate risk prostate cancer; however, challenges remain in accurately delivering treatment to specified targets and determining treatment success. Registered multi-parametric magnetic resonance imaging (MPMRI) acquired before and after treatment can support focal therapy evaluation and optimization; however, contouring variability, when defining the prostate, the clinical target volume (CTV) and the ablation region in images, reduces the precision of quantitative image-based focal therapy evaluation metrics. To inform the interpretation and clarify the limitations of such metrics, we investigated inter-observer contouring variability and its impact on four metrics.

Methods: Pre-therapy and 2-week-post-therapy standard-of-care MPMRI were acquired from 5 focal cryotherapy patients. Two clinicians independently contoured, on each slice, the prostate (pre- and post-treatment) and the dominant index lesion CTV (pre-treatment) in the T2-weighted MRI, and the ablated region (post-treatment) in the dynamic-contrast- enhanced MRI. For each combination of clinician contours, post-treatment images were registered to pre-treatment images using a 3D biomechanical-model-based registration of prostate surfaces, and four metrics were computed: the proportion of the target tissue region that was ablated and the target:ablated region volume ratio for each of two targets (the CTV and an expanded planning target volume). Variance components analysis was used to measure the contribution of each type of contour to the variance in the therapy evaluation metrics.

Conclusions: 14–23% of evaluation metric variance was attributable to contouring variability (including 6–12% from ablation region contouring); reducing this variability could improve the precision of focal therapy evaluation metrics.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Eli Gibson, Ian A. Donaldson, Taimur T. Shah, Yipeng Hu, Hashim U. Ahmed, and Dean C. Barratt "Impact of region contouring variability on image-based focal therapy evaluation", Proc. SPIE 9786, Medical Imaging 2016: Image-Guided Procedures, Robotic Interventions, and Modeling, 97861K (18 March 2016); https://doi.org/10.1117/12.2216654
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Prostate

Image segmentation

Image registration

Magnetic resonance imaging

Prostate cancer

Tissues

Natural surfaces

Back to Top