You have requested a machine translation of selected content from our databases. This functionality is provided solely for your convenience and is in no way intended to replace human translation. Neither SPIE nor the owners and publishers of the content make, and they explicitly disclaim, any express or implied representations or warranties of any kind, including, without limitation, representations and warranties as to the functionality of the translation feature or the accuracy or completeness of the translations.
Translations are not retained in our system. Your use of this feature and the translations is subject to all use restrictions contained in the Terms and Conditions of Use of the SPIE website.
24 June 2014Observation of phase defect on extreme ultraviolet mask using an extreme ultraviolet microscope
Influences of phase defect structures on extreme ultraviolet (EUV) microscope images were examined. Phase defects on the bottom of a multilayer (ML) do not always propagate vertically upward to the ML’s top surface. For this study, two types of masks were prepared. One was an EUV blank with programmed phase defects made of lines in order to analyze the inclination angle of the phase defects. The other was an EUV mask that consists of programmed dot type phase defects 80 nm wide and 2.4 nm high with absorber patterns of half-pitch 88-nm lines-and-spaces. The positions of the phase defects relative to the absorber lines were designed to be shifted accordingly. Transmission electron microscope observations revealed that the line type phase defects starting from the bottom surface of the ML propagated toward the ML’s top surface, while inclined toward the center of the EUV blank. At the distances of 0 and 66 mm from the center of the EUV blank, the inclination angles varied from 0 to 4 deg. The impacts of the inclination angles on EUV microscope images were significant even though the positions of the phase defect relative to the absorber line, as measured by a scanning probe microscope, were the same.