QUBIC (Q and U bolometric interferometer for cosmology) is an international ground-based experiment dedicated to the measurement of the polarized fluctuations of the cosmic microwave background (CMB). It is based on bolometric interferometry, an original detection technique which combines the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province. The QUBIC detection chain consists of 2048 NbSi transition edge sensors (TESs) cooled to 320 mK. The voltage-biased TESs are read out with time domain multiplexing based on superconducting quantum interference devices (SQUIDs) at 1 K and a novel SiGe application-specific integrated circuit (ASIC) at 60 K allowing an unprecedented multiplexing (MUX) factor equal to 128 to be reached. The current QUBIC version is based on a reduced number of detectors (1/4) in order to validate the detection technique. The QUBIC experiment is currently being validated in the lab in Salta (Argentina) before going to the site for observations. This paper presents the main results of the characterization phase with a focus on the detectors and readout system.
The Q and U Bolometric Interferometer for Cosmology (QUBIC) Technical Demonstrator (TD) aiming to shows the feasibility of the combination of interferometry and bolometric detection. The electronic readout system is based on an array of 128 NbSi Transition Edge Sensors cooled at 350mK readout with 128 SQUIDs at 1K controlled and amplified by an Application Specific Integrated Circuit at 40K. This readout design allows a 128:1 Time Domain Multiplexing. We report the design and the performance of the detection chain in this paper. The technological demonstrator unwent a campaign of test in the lab. Evaluation of the QUBIC bolometers and readout electronics includes the measurement of I-V curves, time constant and the Noise Equivalent Power. Currently the mean Noise Equivalent Power is ~ 2 x 10-16W= p √Hz
The X-IFU instrument is one of the payloads of the ESA ATHENA observatory, offering an unprecedented high spectral resolution of X-ray. In the readout chain of the X-IFU instrument, the first warm stage is the WFEE subsystem. It comprises low-noise amplifiers, current sources, a serial bus and housekeeping elements. Until now, three ASICs dedicated to this subsystem have been developed and fully characterised. They all use a 350 nm SiGe BiCMOS technology. The first version was to verify the feasibility of basic topologies and radiation robustness of the technology, that has already been reported in previous papers. Based on the results of the first version, the second version was for testing the low-noise amplifier, the serial bus and the thermometer and the third ASIC is a complete version integrating all the components of one WFEE FDM channel. This paper presents these two ASICs and their representative experimental results as an update on the WFEE microelectronics. Moreover, following the shift of the readout multiplexing scheme from FDM to TDM, a new version adapting to technical changes has also been developed and current manufacturing. It is discussed at the end of the paper.
QUBIC (a Q and U Bolometric Interferometer for Cosmology) is a next generation cosmology experiment designed to detect the B-mode polarisation of the Cosmic Microwave Background (CMB). A B-mode detection is hard evidence of Inflation in the ΛCDM model. QUBIC aims to accomplish this by combining novel technologies to achieve the sensitivity required to detect the faint B-mode signal. QUBIC uses technologies such as a rotating half-wave plate, cryogenics, interferometric horns with self-calibration switches and transition edge sensor bolometers. A Technical Demonstrator (TD) is currently being calibrated in APC in Paris before observations in Argentina in 2021. As part of the calibration campaign, the spectral response of the TD is measured to test and validate QUBIC's spectro-imaging capability. This poster gives an overview of the methods used to measure the spectral response and a comparison of the instrument data with theoretical predictions and optical simulations.
QUBIC, the Q & U Bolometric Interferometer for Cosmology, is a novel ground-based instrument that aims to measure the extremely faint B-mode polarisation anisotropy of the cosmic microwave background at intermediate angular scales (multipoles of 𝑙 = 30 − 200). Primordial B-modes are a key prediction of Inflation as they can only be produced by gravitational waves in the very early universe. To achieve this goal, QUBIC will use bolometric interferometry, a technique that combines the sensitivity of an imager with the immunity to systematic effects of an interferometer. It will directly observe the sky through an array of back-to-back entry horns whose beams will be superimposed using a cooled quasioptical beam combiner. Images of the resulting interference fringes will be formed on two focal planes, each tiled with transition-edge sensors, cooled down to 320 mK. A dichroic filter placed between the optical combiner and the focal planes will select two frequency bands (centred at 150 GHz and 220 GHz), one frequency per focal plane. Polarization modulation will be achieved using a cold stepped half-wave plate (HWP) and polariser in front of the sky-facing horns.
The full QUBIC instrument is described elsewhere1,2,3,4; in this paper we will concentrate in particular on simulations of the optical combiner (an off-axis Gregorian imager) and the feedhorn array. We model the optical performance of both the QUBIC full module and a scaled-down technological demonstrator which will be used to validate the full instrument design. Optical modelling is carried out using full vector physical optics with a combination of commercial and in-house software. In the high-frequency channel we must be careful to consider the higher-order modes that can be transmitted by the horn array. The instrument window function is used as a measure of performance and we investigate the effect of, for example, alignment and manufacturing tolerances, truncation by optical components and off-axis aberrations. We also report on laboratory tests carried on the QUBIC technological demonstrator in advance of deployment to the observing site in Argentina.
QUBIC, the Q & U Bolometric Interferometer for Cosmology, is a novel ground-based instrument that has been designed to measure the extremely faint B-mode polarisation anisotropy of the cosmic microwave background at intermediate angular scales (multipoles of 𝑙 = 30 − 200). Primordial B-modes are a key prediction of Inflation as they can only be produced by gravitational waves in the very early universe. To achieve this goal, QUBIC will use bolometric interferometry, a technique that combines the sensitivity of an imager with the systematic error control of an interferometer. It will directly observe the sky through an array of 400 back-to-back entry horns whose signals will be superimposed using a quasi-optical beam combiner. The resulting interference fringes will be imaged at 150 and 220 GHz on two focal planes, each tiled with NbSi Transition Edge Sensors, cooled to 320 mK and read out with time-domain multiplexing. A dichroic filter placed between the optical combiner and the focal planes will select the two frequency bands. A very large receiver cryostat will cool the optical and detector stages to 40 K, 4 K, 1 K and 320 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. Polarisation modulation and selection will be achieved using a cold stepped half-wave plate (HWP) and polariser, respectively, in front of the sky-facing horns. A key feature of QUBIC’s ability to control systematic effects is its ‘self-calibration’ mode where fringe patterns from individual equivalent baselines can be compared. When observing, however, all the horns will be open simultaneously and we will recover a synthetic image of the sky in the I, Q and U Stokes’ parameters. The synthesised beam pattern has a central peak of approximately 0.5 degrees in width, with secondary peaks further out that are damped by the 13-degree primary beam of the horns. This is Module 1 of QUBIC which will be installed in Argentina, near the city of San Antonio de los Cobres, at the Alto Chorrillos site (4869 m a.s.l.), Salta Province. Simulations have shown that this first module could constrain the tensor-to-scalar ratio down to σ(r) = 0.01 after a two-year survey. We aim to add further modules in the future to increase the angular sensitivity and resolution of the instrument. The QUBIC project is proceeding through a sequence of steps. After an initial successful characterisation of the detection chain, a technological demonstrator is being assembled to validate the full instrument design and to test it electrically, thermally and optically.
The technical demonstrator is a scaled-down version of Module 1 in terms of the number of detectors, input horns and pulse tubes and a reduction in the diameter of the combiner mirrors and filters, but is otherwise similar. The demonstrator will be upgraded to the full module in 2019. In this paper we give an overview of the QUBIC project and instrument.
QUBIC, the QU Bolometric Interferometer for Cosmology, is a novel forthcoming instrument to measure the B-mode polarization anisotropy of the Cosmic Microwave Background. The detection of the B-mode signal will be extremely challenging; QUBIC has been designed to address this with a novel approach, namely bolometric interferometry. The receiver cryostat is exceptionally large and cools complex optical and detector stages to 40 K, 4 K, 1 K and 350 mK using two pulse tube coolers, a novel 4He sorption cooler and a double-stage 3He/4He sorption cooler. We discuss the thermal and mechanical design of the cryostat, modelling and thermal analysis, and laboratory cryogenic testing.
QUBIC (the Q and U Bolometric Interferometer for Cosmology) is a ground-based experiment which seeks to improve the current constraints on the amplitude of primordial gravitational waves. It exploits the unique technique, among Cosmic Microwave Background experiments, of bolometric interferometry, combining together the sensitivity of bolometric detectors with the control of systematic effects typical of interferometers. QUBIC will perform sky observations in polarization, in two frequency bands centered at 150 and 220 GHz, with two kilo-pixel focal plane arrays of NbSi Transition-Edge Sensors (TES) cooled down to 350 mK. A subset of the QUBIC instrument, the so called QUBIC Technological Demonstrator (TD), with a reduced number of detectors with respect to the full instrument, will be deployed and commissioned before the end of 2018.
The voltage-biased TES are read out with Time Domain Multiplexing and an unprecedented multiplexing (MUX) factor equal to 128. This MUX factor is reached with two-stage multiplexing: a traditional one exploiting Superconducting QUantum Interference Devices (SQUIDs) at 1K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K. The former provides a MUX factor of 32, while the latter provides a further 4. Each TES array is composed of 256 detectors and read out with four modules of 32 SQUIDs and two ASICs. A custom software synchronizes and manages the readout and detector operation, while the TES are sampled at 780 Hz (100kHz/128 MUX rate).
In this work we present the experimental characterization of the QUBIC TES arrays and their multiplexing readout chain, including time constant, critical temperature, and noise properties.
The X-IFU is one of the two instruments of the ESA ATHENA space mission, at present in feasibility phase (phase A). It is an X-Ray spectral imager designed to have an unprecedented 2.5 eV spectral resolution at 6 keV. In the readout chain of the X-IFU, the first stage working at room temperature is the WFEE subsystem, currently being developed at APC laboratory. It will include low-noise amplifiers, current sources, RS485/I2C digital interfaces and housekeeping elements. A first ASIC dedicated to this subsystem has been designed and tested. The basic functions of the main components of the WFEE and its radiation-hardened abilities have been evaluated. According to the measurement results, a second ASIC is being developed, aiming to comply with the WFEE requirements in the X-IFU readout chain.
Remnant radiation from the early universe, known as the Cosmic Microwave Background (CMB), has been redshifted and cooled, and today has a blackbody spectrum peaking at millimetre wavelengths. The QUBIC (Q&U Bolometric Interferometer for Cosmology) instrument is designed to map the very faint polaristion structure in the CMB. QUBIC is based on the novel concept of bolometric interferometry in conjunction with synthetic imaging. It will have a large array of input feedhorns, which creates a large number of interferometric baselines.
The beam from each feedhorn is passed through an optical combiner, with an off-axis compensated Gregorian design, to allow the generation of the synthetic image. The optical-combiner will operate in two frequency bands (150 and 220 GHz with 25% and 18.2 % bandwidth respectively) while cryogenically cooled TES bolometers provide the sensitivity required at the image plane.
The QUBIC Technical Demonstrator (TD), a proof of technology instrument that contains 64 input feed-horns, is currently being built and will be installed in the Alto Chorrillos region of Argentina. The plan is then for the full QUBIC instrument (400 feed-horns) to be deployed in Argentina and obtain cosmologically significant results.
In this paper we will examine the output of the manufactered feed-horns in comparison to the nominal design. We will show the results of optical modelling that has been performed in anticipation of alignment and calibration of the TD in Paris, in particular testing the validity of real laboratory environments. We show the output of large calibrator sources (50 ° full width haf max Gaussian beams) and the importance of accurate mirror definitions when modelling large beams. Finally we describe the tolerance on errors of the position and orientation of mirrors in the optical combiner.
The focal plane of the X-Ray Integral Field Unit (X-IFU) instrument of the Advanced Telescope for High-Energy Astrophysics observatory is composed of 3840 microcalorimeters. These sensors, based on superconducting transition edge sensors (TES), are read out through a frequency multiplexer. A “base-band feedback” suppresses all the carriers of the multiplexed signal in the superconducting quantum interference devices input coil (cryogenic readout). However, the loop gain of this feedback is too small (less than 10 in the present baseline of the phase A mission) to strongly compensate the readout gain drifts. An onboard x-ray source is considered to calibrate the gain of the full instrument. However, in-flight calibration time must be minimized, which leads to a requirement on the gain stability larger than 10−4 over a long duration (between each calibration) to reach the challenging energy resolution goal of 2.5 eV at 6 keV of the X-IFU. A significant part of this gain is provided by a low-noise amplifier in the warm front-end electronics (WFEE). To reach such gain stability over more than a dozen minutes, this noncooled amplifier has to cope with the temperature and supply voltage variations. Moreover, mainly for noise reasons, a common large loop gain with feedback cannot be used. We propose a new amplifier topology using diodes as loads of a differential amplifier to provide a fixed voltage gain, independent of the temperature and of the bias fluctuations. This amplifier is designed using 350-nm SiGe BiCMOS technology and is part of an integrated circuit developed for the WFEE. Our simulations provide the expected gain and noise performances. Comparison with standard resistive loaded differential pair clearly shows the advantages of the proposed amplifier topology with a gain drift decreased by more than an order of magnitude. Performances of this diode loaded amplifier are discussed in the context of the X-IFU requirements.
Big Bang cosmologies predict that the cosmic microwave background (CMB) contains faint temperature and polarisation
anisotropies imprinted in the early universe. ESA's PLANCK satellite has already measured the temperature
anisotropies1 in exquisite detail; the next ambitious step is to map the primordial polarisation signatures which are
several orders of magnitude lower. Polarisation E-modes have been measured2 but the even-fainter primordial B-modes
have so far eluded detection. Their magnitude is unknown but it is clear that a sensitive telescope with exceptional
control over systematic errors will be required.
QUBIC3 is a ground-based European experiment that aims to exploit the novel concept of bolometric interferometry in
order to measure B-mode polarisation anisotropies in the CMB. Beams from an aperture array of corrugated horns will
be combined to form a synthesised image of the sky Stokes parameters on two focal planes: one at 150 GHz the other at
220 GHz. In this paper we describe recent optical modelling of the QUBIC beam combiner, concentrating on modelling
the instrument point-spread-function and its operation in the 220-GHz band. We show the effects of optical aberrations
and truncation as successive components are added to the beam path. In the case of QUBIC, the aberrations introduced
by off-axis mirrors are the dominant contributor. As the frequency of operation is increased, the aperture horns allow up to five hybrid modes to propagate and we illustrate how the beam pattern changes across the 25% bandwidth. Finally we
describe modifications to the QUBIC optical design to be used in a technical demonstrator, currently being manufactured
for testing in 2016.
The focal plane of the X-ray Integral Field Unit (X-IFU) instrument of the Athena observatory is composed of about 4000 micro-calorimeters. These sensors, based on superconducting Transition Edge Sensors, are read out through a frequency multiplexer and a base-band feedback to linearize SQUIDs. However, the loop gain of this feedback is lower than 10 in the modulated TES signal bandwidth, which is not enough to fix the gain of the full readout chain. Calibration of the instrument is planned to be done at a time scale larger than a dozen minutes and the challenging energy resolution goal of 2.5 eV at 6 keV will probably require a gain stability larger than 10-4 over a long duration. A large part of this gain is provided by a Low-Noise Amplifier (LNA) in the Warm Front-End Electronics (WFEE). To reach such gain stability over more than a dozen minutes, this non-cooled amplifier has to cope with the temperature and supply voltage variations. Moreover, mainly for noise reasons, common large loop gain with feedback can not be used. We propose a new amplifier topology using diodes as loads of a differential amplifier to provide a fixed voltage gain, independent of the temperature and of the bias fluctuations. This amplifier is designed using a 350 nm SiGe BiCMOS technology and is part of an integrated circuit developed for the WFEE. Our simulations provide the expected gain drift and noise performances of such structure. Comparison with standard resistive loaded differential pair clearly shows the advantages of the proposed amplifier topology with a gain drift decreasing by more than an order of magnitude. Performances of this diode loaded amplifier are discussed in the context of the X-IFU requirements.
F. Pajot, D. Prele, J. Zhong, Y. Atik, B. Bélier, L. Bergé, G. Bordier, E. Bréelle, L. Dumoulin, C. Evesque, F. Gadot, B. Leriche, S. Marnieros, J. Martino, M. Piat, S.-C. Shi, F. Voisin
The achievement of the Planck and Herschel space missions in the submillimeter and millimeter range was made
possible by a continuous effort on detector developments. Now limited by the intrinsic fluctuations of the radiation
coming from the astronomical sources themselves, the sensitivity improvement requires the development of large arrays
of detectors filling the focal plane of the telescopes. We present here the development of a TES array using NbSi sensors
on SiN membranes. The readout electronics is based on SQUIDs and a cooled SiGe ASIC multiplexer. The detector is
coupled with the input radiation by means of antenna. The present goal performance is adapted for the realisation of a
ground based millimeter camera.
Bolometers cooled to very low temperature are currently the most sensitive detectors for low spectral resolution
detection of millimetre and sub-millimetre wavelengths. The best performances of the state-of-the-art bolometers allow
to reach sensitivities below the photon noise of the Cosmic Microwave Background for example. Since 2003, a french
R&D effort called DCMB ("Developpement Concerte de Matrices de Bolometres") has been organised between different
laboratories to develop large bolometers arrays for astrophysics observations. Funded by CNES and CNRS, it is intended
to get a coherent set of competences and equipments to develop very cold bolometers arrays by microfabrication. Two
parallel developments have been made in this collaboration based on the NbSi alloy either semi-conductive or
superconducting depending on the proportion of Nb. Multiplexing schemes have been developed and demonstrated for
these two options. I will present the latest developments made in the DCMB collaboration and future prospects.
This paper presents an ultra low noise instrumentation based on cryogenic electronic integrated circuits (ASICs :
Application Specific Integrated Circuits). We have designed successively two ASICs in standard BiCMOS SiGe 0.35 μm
technology that have proved to be operating at cryogenic temperatures. The main functions of these circuits are the
readout and the multiplexing of SQUID/TES arrays. We report the cryogenic operation of a first ASIC version dedicated
to the readout of a 2×4 pixel demonstrator array. We particularly emphasize on the development and the test phases of an
ultra low noise (0.2 nV/√Hz) cryogenic amplifier designed with two multiplexed inputs. The cryogenic SiGe amplifier
coupled to a SQUID in a FLL operating at 4.2 K is also presented. We finally report on the development of a second
version of this circuit to readout a 3×8 detectors array with improved noise performances and upgraded functionalities.
Future space experiments will require large arrays of sensitive detectors in the submillimeter and millimeter range.
Superconducting transition-edge sensors (TESs) are currently under heavy development to be used as ultra sensitive
bolometers. In addition to good performance, the choice of material depends on long term stability (both physical and
chemical) along with a good reproducibility and uniformity in fabrication. For this purpose we are investigating the
properties of co-evaporated NbSi thin films. NbSi is a well-known alloy for use in resistive thermometers. We present a
full low temperature characterization of superconductive NbSi films. In order to tune the critical temperature of the NbSi
thermometers down to the desired range, we have to adjust the concentration of niobium in the NbSi alloy. Tests are
made using 4He-cooled cryostats, 300mK 3He mini-fridges, Resistance Bridges and commercial SQUID. Measured
parameters are the critical temperature, the sharpness of the transition. Noise measurements are on-going.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.