The hydrodynamic rebalancing laser (HRL) procedure is an ophthalmic therapy based on the administration of subthreshold infrared (810 nm) laser light to selected areas on the retina to treat various retina diseases. Heterogeneities of tissue response are observed, including undesired retinal damages. Variations of tissue absorbance were hypothesized to cause this uneven response. Irradiation parameters (diameter=100 μm; power=1 W; irradiation time: 50 to 200 ms), location and tissue response were studied in 16 patients (20 eyes, 2535 laser spots) to discover any correlation between tissue response and normalized fundus reflectance at 810 nm. The results demonstrate a complex relationship between some pathologies and occurrences of retinal damage, but no clear correlation. One possible reason is that the resolution of reflectance images is insufficient to see "small" (40 μm or less) absorption centers, particularly deep-seated ones. Additionally, tissue parameters other than variations of the fundus optical absorption influence heat diffusion and temperature increases. Monitoring or individualizing the light dose in HRL therapy, or any similar infrared diode laser-based therapy will require more sophisticated technologies, including imaging the retina's reflectance with an improved resolution, as well as refined methods to detect complex correlations between retinal damage and specific pathologies.
Tissular oxygen concentration plays a key role during photodynamic therapy (PDT). Therefore, monitoring its local oxygen partial pressure (pO2) may help predict and/or control the outcome of a PDT treatment. The first real-time, in vivo measurements of the pO2 in the chicken egg's chorioallantoic membrane, using the delayed fluorescence of photoactivable porphyrins (PAPs), including protoporphyrin IX (PpIX), as monitored with a dedicated optical, fiber-based, time-resolved spectrometer, are reported here. The formation of PAPs/PpIX, photosensitizers of extensive clinical use, was induced in the chicken egg's chorioallantoic membrane (CAM) with aminolevulinic acid. An excellent correlation between the vascular damage induced by PDT and the reduction in tissular pO2 is found. This study suggests that clinical measurement of the pO2 using the PAPs'/PpIX's delayed fluorescence (DF) may be used to individualize in real time the PDT light dose applied.
A new optical-fiber-based spectrofluorometer for in vivo or in vitro detection of delayed fluorescence is presented and characterized. This compact setup is designed so that it can be readily adapted for future clinical use. Optical excitation is done with a nitrogen laser-pumped, tunable dye laser, emitting in the UV-vis part of the spectrum. Excitation and luminescence signals are carried to and from the biological tissues under investigation, located out of the setup enclosure, by a single optical fiber. These measurements, as well as measurements performed without a fiber on in vitro samples in a thermostable quartz cell, in a controlled-atmosphere enclosure, are possible due to the efficient collection of the laser-induced luminescence light which is collected and focused on the detector with a high aperture parabolic mirror. The detection is based on a gated photomultiplier which allows for time-resolved measurements of the delayed fluorescence intensity. Thus, relevant luminescence lifetimes, typically in the sub-microsecond-to-millisecond range, can be measured with near total rejection of the sample's prompt fluorescence. The instrument spectral and temporal resolution, as well as its sensitivity, is characterized and measurement examples are presented. The primary application foreseen for this setup is the monitoring and adjustment of the light dose delivered during photodynamic therapy.
Based on the concept of Mazzone et al., we have designed a novel system to be used simultaneously as an input and output device for designing, presenting, or recognizing objects in three-dimensional space. Unlike state of the art stereoscopic display technologies that generate a virtual image of a three-dimensional object, the proposed system, a “digital clay” like device, physically imitates the desired object. The object can not only be touched and explored
intuitively but also deform itself physically. In order to succeed in developing such a deformable structure, self-actuating ionic polymer-metal composite (IPMC) materials are proposed. IPMC is a type of electro active polymer (EAP) and has recently been drawing much attention. It has high force to weight ratio and shape flexibility, making it ideal for robotic applications. This paper introduces the first steps and results in the attempt of developing such a structure. A strip consisting of four actuators arranged in line was fabricated and evaluated, showing promising capabilities in deforming two-dimensionally. A simple model to simulate the deformation of an IPMC actuator using finite element methods (FEM) is
also proposed and compared with the experimental results. The model can easily be implemented into computer aided engineering (CAE) software. This will expand the application possibilities of IPMCs. Furthermore, a novel method for creating multiple actuators on one membrane with a laser machining tool is introduced.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.