The MATS satellite aims at observing airglow and noctilucent clouds in the mesosphere. The main instrument consists of a six channels limb imager in the near-ultraviolet and near-infrared. A high signal-to-noise ratio is required for detecting these mesospheric phenomena: 100 and 500 for ultraviolet and infrared, respectively. This is achieved by an optical design minimizing stray-light, but also with a dedicated design of the read-out analogue chain for the CCD on each channel. The requirements and expected light level on the imaging channels are brie y discussed before focusing on the CCD read-out analogue chain, for which the design and performances are presented.
G. Giono, Y. Katsukawa, R. Ishikawa, N. Narukage, R. Kano, M. Kubo, S. Ishikawa, T. Bando, H. Hara, Y. Suematsu, A. Winebarger, K. Kobayashi, F. Auchère, J. Trujillo Bueno
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument developed at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. The instrument main scientific goal is to achieve polarization measurement of the Lyman-α line at 121.56 nm emitted from the solar upper-chromosphere and transition region with an unprecedented 0.1% accuracy. The optics are composed of a Cassegrain telescope coated with a "cold mirror" coating optimized for UV reflection and a dual-channel spectrograph allowing for simultaneous observation of the two orthogonal states of polarization. Although the polarization sensitivity is the most important aspect of the instrument, the spatial and spectral resolutions of the instrument are also crucial to observe the chromospheric features and resolve the Ly-α profiles. A precise alignment of the optics is required to ensure the resolutions, but experiments under vacuum conditions are needed since Ly-α is absorbed by air, making the alignment experiments difficult. To bypass this issue, we developed methods to align the telescope and the spectrograph separately in visible light. We explain these methods and present the results for the optical alignment of the CLASP telescope and spectrograph. We then discuss the combined performances of both parts to derive the expected resolutions of the instrument, and compare them with the flight observations performed on September 3rd 2015.
We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman‐alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman‐alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non‐ uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.
The Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP) is a sounding-rocket instrument currently under development at the National Astronomical Observatory of Japan (NAOJ) as a part of an international collaboration. CLASP’s optics are composed of a Cassegrain telescope and a spectro-polarimeter which are designed to achieve an unprecedentedly accurate polarization measurement of the Ly-α line at 121.6nm emitted from the solar upper-chromosphere and transition region. CLASP’s first flight is scheduled for August 2015. Reaching such accuracy requires a careful alignment of the optical elements to optimize the image quality at 121.6 nm. However Ly-α is absorbed by air and therefore the optics alignment has to be done under vacuum condition which makes any experiment difficult. To bypass this issue, we proposed to align the telescope and the spectrograph separately in visible light. Hence we present our alignment procedure for both telescope and spectro-polarimeter. We will explain details about the telescope preliminary alignment before mirrors coating, which was done in April 2014, present the telescope combined optical performance and compare them to CLASP tolerance. Then we will present details about an experiment designed to confirm our alignment procedure for the CLASP spectro-polarimeter. We will discuss the resulting image quality achieved during this experiment and the lessons learned.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.