This report is the second part of a comprehensive two-part series aimed at reviewing an extensive and diverse toolkit of novel methods to explore brain health and function. While the first report focused on neurophotonic tools mostly applicable to animal studies, here, we highlight optical spectroscopy and imaging methods relevant to noninvasive human brain studies. We outline current state-of-the-art technologies and software advances, explore the most recent impact of these technologies on neuroscience and clinical applications, identify the areas where innovation is needed, and provide an outlook for the future directions.
The application of functional near-infrared spectroscopy (fNIRS) in the neurosciences has been expanding over the last 40 years. Today, it is addressing a wide range of applications within different populations and utilizes a great variety of experimental paradigms. With the rapid growth and the diversification of research methods, some inconsistencies are appearing in the way in which methods are presented, which can make the interpretation and replication of studies unnecessarily challenging. The Society for Functional Near-Infrared Spectroscopy has thus been motivated to organize a representative (but not exhaustive) group of leaders in the field to build a consensus on the best practices for describing the methods utilized in fNIRS studies.
Our paper has been designed to provide guidelines to help enhance the reliability, repeatability, and traceability of reported fNIRS studies and encourage best practices throughout the community. A checklist is provided to guide authors in the preparation of their manuscripts and to assist reviewers when evaluating fNIRS papers.
Timing of the intervention for intracranial hematomas is critical for its success, specifically since expansion of the hemorrhage can result in debilitating and sometimes fatal outcomes. Led by Britton Chance, we and an extended team from University of Pennsylvania, Baylor and Drexel universities developed a handheld brain hematoma detector for early triage and diagnosis of head trauma victims. After obtaining de novo Food and Drug Administration clearance, over 200 systems are deployed in all Marine battalion aid stations around the world. Infrascanner, a handheld brain hematoma detection system, is based on the differential near-infrared light absorption of the injured versus the noninjured part of brain. About 12 independent studies have been conducted in the USA, Canada, Spain, Italy, the Netherlands, Germany, Russia, Poland, Afghanistan, India, China, and Turkey. Here, we outline the background and design of the device as well as clinical studies with a total of 1293 patients and 203 hematomas. Infrascanner demonstrates high sensitivity (adults: 92.5% and children: 93%) and specificity (adults: 82.9% and children: 86.5%) in detecting intracranial hematomas >3.5 mL in volume and <2.5 cm from the surface of the brain. Infrascanner is a clinically effective screening solution for head trauma patients in prehospital settings where timely triage is critical.
Transcranial magnetic stimulation (TMS) is a noninvasive method used to excite or inhibit cortical activity for experimental, diagnostic, and therapeutic interventions. However, nonmotor regions of the brain targeted in TMS therapies, such as the dorsolateral prefrontal cortex (DLPFC), offer no extrinsic response to stimulation, resulting in a need for a practical method for the evaluation of treatment. We sought to determine the capability of a continuous-wave light emitting diodes (LED)-based functional near-infrared spectroscopy (fNIRS) system to measure evoked cortical hemoglobin changes in the DLPFC during the simultaneous application of TMS to the left-DLPFC under brief stimulation paradigms used in the clinic. Seventeen healthy participants received short TMS trains at F3 in four different stimulation conditions (single pulse, high frequency, intermittent theta burst, and sham) while adjacent fNIRS measurements were recorded. Ten 2-s trains of each stimulation type were delivered with an intertrial interval of 40 s. Results indicated that high-frequency stimulation produces a larger and more evident response than other measured conditions. These findings show that a continuous-wave LED-based fNIRS system can be used to measure TMS-evoked responses and that future TMS applications can benefit from concurrent assessment of localized cortical activation changes.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.