High Performance Computing based simulations are crucial in Astrophysics and Cosmology, helping scientists investigate and understand complex astrophysical phenomena. Taking advantage of Exascale computing capabilities is essential for these efforts. However, the unprecedented architectural complexity of exascale systems impacts simulation codes. The SPACE Center of Excellence aims to re-engineer key astrophysical codes to adapt to these new computational challenges by adopting innovative programming paradigms and software solutions. Through co-design activities, SPACE brings together scientists, code developers, HPC experts, hardware manufacturers, and software developers. This collaboration enhances exascale astrophysics and cosmology applications, promoting the use of exascale and post-exascale computing capabilities. Additionally, SPACE addresses high-performance data analysis for the massive data outputs from exascale simulations, using machine learning and visualization tools. The project facilitates application deployment across platforms by focusing on code repositories and data sharing, integrating European astrophysical communities around exascale computing with standardized software and data protocols. In this paper, we present the SPACE Center of Excellence and the preliminary results achieved by the project.
LUCI (former LUCIFER) is the full cryogenic near-infrared multi-object spectrograph and imager at the LBT. It presently allows for seeing limited imaging and multi-object spectroscopy at R~2000-4000 in a 4x4arcmin2 FOV from 0.9 to 2.5 micron. We report on the instrument performance and the lessons learned during the first two years on sky from a technical and operational point of view. We present the upcoming detector upgrade to Hawaii-2 RG arrays and the operating modes to utilize the binocular mode, the LBT facility AO system for diffraction limited imaging as well as to use the wide-field AO correction afforded by the multi-laser GLAO System ARGOS in multi-object spectroscopy.
Walter Seifert, Nancy Ageorges, Michael Lehmitz, Peter Buschkamp, Volker Knierim, Kai Polsterer, Andre Germeroth, Anna Pasquali, Vianak Naranjo, Marcus Jütte, Carmen Feiz, Hans Gemperlein, Reiner Hofmann, Werner Laun, Reinhard Lederer, Rainer Lenzen, Ulrich Mall, Holger Mandel, Peter Müller, Andreas Quirrenbach, Ludwig Schäffner, Clemens Storz, Peter Weiser
LUCIFER1 is a NIR camera and spectrograph installed at the Large Binocular Telescope (LBT). Working in
the wavelength range of 0.9-2.5micron, the instrument is designed for direct imaging and spectroscopy with 3
different cameras. A set of longslit masks as well as up to 23 user defined (MOS) masks are available. The set
of user defined masks can be exchanged while the instrument is at operating temperature.
Extensive tests have been done on the electro-mechanical functions, image motion due to flexure, optical
quality, instrument software, calibration and especially on the multi-object spectroscopy. Also a detailed characterization
of the instrument's properties in the different observing modes has been carried out. Results are
presented and compared to the specifications.
The LUCIFER-MOS unit is the full cryogenic mask-exchange unit for the near-infrared multi-object spectrograph
LUCIFER at the Large Binocular Telescope. We present the design and functionality of this unique device. In LUCIFER
the masks are stored, handled, and placed in the focal plane under cryogenic conditions at all times, resulting in very low
thermal background emission from the masks during observations. All mask manipulations are done by a novel
cryogenic mask handling robot that can individually address up to 33 fixed and user-provided masks and place them in
the focal plane with high accuracy. A complete mask exchange cycle is done in less than five minutes and can be run in
every instrument position and state reducing instrument setup time during science observations to a minimum. Exchange
of old and new MOS masks is likewise done under cryogenic conditions using a unique exchange drive mechanism and
two auxiliary cryostats that attach to the main instrument cryostat.
The successful roll-out of the control software for a complex NIR imager/spectrograph with MOS calls for
flexible development strategies due to changing requirements during different phases of the project. A waterfall
strategy used in the beginning has to change to a more iterative and agile process in the later stages. The
choice of an appropriate program language as well as suitable software layout is crucial. For example the
software has to accomplish multiple demands of different user groups, including a high level of flexibility for
later changes and extensions. Different access levels to the instrument are mandatory to afford direct control
mechanisms for lab operations and inspections of the instrument as well as tools to accomplish efficient science
observations. Our hierarchical software structure with four layers of increasing abstract levels and the use of an
object oriented language ideally supports these requirements. Here we describe our software architecture, the
software development process, the different access levels and our commissioning experiences with LUCIFER 1.
LUCIFER 1 is the rst of two identical camera-spectrograph units installed at the LBT (Large Binocular Telescope)
on Mount Graham in Arizona. Its commissioning took place between September 2008 and November
2009 and has immediately been followed by science operations since December 2009.
LUCIFER has a 4x4 arcminute eld of view. It is equipped with a 2048x2048 pixel HAWAII-2 array, suitable
lters (broad-band z, J, H, K & Ks plus 12 medium and narrow band near-infrared lters) and three gratings for
spectroscopy for a resolution of up to 15000. LUCIFER has 3 cameras: two specic for seeing limited imaging
(the N3.75 camera, with 0.12"/pixel) and spectroscopy (the N1.8 camera, with 0.25"/pixel) and one for diraction
limited observations (the N30 camera). We report here about the completed seeing-limited commissioning, thus
using only two of the cameras.
LUCIFER is a NIR spectrograph and imager (wavelength range 0.9 to 2.5 micron) for the Large Binocular
Telescope (LBT) on Mt. Graham, Arizona, working at cryogenic temperatures of less than 70K. Two instruments
are built by a consortium of five German institutes and will be mounted at the bent Gregorian foci of the two
individual telescope mirrors. Three exchangable cameras are available for imaging and spectroscopy: two of
them are optimized for seeing-limited conditions, a third camera for the diffraction limited case will be used with
the LBT adaptive secondary mirror working. Up to 33 exchangeable masks are available for longslit or multi-object
spectroscopy (MOS) over the full field of view (FOV). Both MOS-units (LUCIFER 1 and LUCIFER
2) and the auxiliary cryostats together with the control electronics have been completed. The observational
software-package is in its final stage of preparation.
After the total integration of LUCIFER 1 extensive tests were done for all electro-mechanical functions and
the verification of the instrument started. The results of the tests are presented in detail and are compared with
the specifications.
LUCIFER (LBT NIR Spectrograph Utility with Camera and Integral-Field
Unit for Extragalactic Research) is a NIR spectrograph and imager for
the LBT (Large Binocular Telescope) working in the wavelength range from 0.9 to 2.5 microns. Two instruments are built by a consortium of
five German institutes (Landessternwarte Heidelberg (LSW), Max Planck
Institut for Astronomy (MPIA), Max Planck Institut for Extraterrestric Physics (MPE), Astronomical Institut of the Ruhr-University Bochum (AIRUB) and Fachhochschule for Technics and Design Mannheim (FHTG).
All major components for the first instrument have been manufactured or are in the final stage of procurement. While integration and testing of LUCIFER 1 started in spring 2006 at the MPIA in Heidelberg, the cryostat for LUCIFER 2 has been sent to the MPE in Garching for system integration tests of the MOS-unit and testing of the mask cabinet exchange. The control electronics for the basic instrument has been manufactured, the MOS control electronics has been integrated and is being debugged. The MOS control software is under development by AIRUB. Fabrication and integration of components for LUCIFER 2 have started.
The LUCIFER instrument is a near infrared spectrograph/imager with MOS for the Large Binocular Telescope.
Here we present the final software design, the interrelation of the software packages and the used hardware
architecture. The software package is completely running under Java using intensively its Remote Method
Invocation (RMI) mechanisms in a distributed system environment. The use of Java helped us to cope with a
small amount of available manpower for the SW development, providing many native built-in Java methods and
classes, which speed up the development process a lot. The control software will be finally installed on a Solaris
OS, hosted on a Sun Fire V880 server, which results from a specific hardware constraint. For testing purposes a
standard Linux environment is used. This shows another big Java advantage, the platform independency. The
"First Light" of LUCIFER 1 is estimated for summer/fall 2007, following LUCIFER 2 one year later.
We present the concept and design of the interaction between users and the LUCIFER Control Software Package.
The necessary functionality that must be provided to a user depends on and differs greatly for the different user
types (i.e., engineers and observers). While engineers want total control over every service provided by the
software system, observers are typically only interested in a fault tolerant and efficient user interface that helps
them to carry out their observations in the best possible way during the night. To provide the functionality
engineers need, direct access to a service is necessary. This may harbor a possible threat to the instrument in
the case of a faulty operation by the engineer, but is the only way to test every unit during integration and
commissioning of the instrument, and for service time later on. The observer on the other hand should only have
indirect access to the instrument, controlled by an instrument manager service that ensures the necessary safety
checks so that no harm can be done to the instrument.
Our design of the user interaction provides such an approach on a level that is transparent to any interaction
component regardless of interface type (i.e., textual or graphical). Using the interface and inheritance concepts
of the Java Programming Language and its tools to create graphical user interfaces, it is possible to provide the
necessary level of flexibility for the different user types on one side, while ensuring maximum reusability of code
on the other side.
Lucifer VR is a virtually realized instrument that was build in order to allow improved pre-integration software tests,
training of observers as well as providing educational access. Beside testing the instrument hardware in combination with
e.g. a telescope simulator, software tests need to be done. A virtual instrument closes the gap between regression tests
and testing the control software with the integrated instrument. Lucifer VR allows much earlier tests and reduces the
amount of time needed to combine the software with the hardware. By modeling the instrument in a simulator, motion
times can be calculated very easily and the position of all instrument units can be traced. Especially when using complex
mechanisms like a MOS unit a virtual instrument makes software development less time consuming. Lucifer VR consists
of three parts; one for handling the communication, another to simulate the hardware and finally a part to visualize the
whole instrument in three dimensions.
The LUCIFER MOS unit has been designed to exchange long-slit and multi-slit masks between two mask storage cabinets and the focal plane area. In combination with auxiliary cryostats, the MOS unit also permits the exchange of cold mask cabinets between LUCIFER and the auxiliary cryostats. Main functional components of the MOS unit are: a focal plane interface accepting the active mask, a mask handling unit transporting the masks between the focal plane mount and their storage locations, a stationary and an exchangeable cabinet holding 10 longslit and 23 multi-slit masks respectively, the translation drives for the exchangeable cabinet and the mask handling unit, and the mask locking unit securing the masks in their cabinets. For mask cabinet exchange, the LUCIFER cryostat as well as the auxiliary cryostats are equipped with 32 cm clear diameter gate valves. A test cryostat has been built to test all MOS unit functions at LN2 temperature. Most of the MOS unit components have been completed. System tests at ambient have started. First results are presented.
LUCIFER (LBT NIR Spectrograph Utility with Camera and Integral-Field
Unit for Extragalactic Research) is a NIR spectrograph and imager for
the LBT (Large Binocular Telescope) working in the wavelength range from 0.9 to 2.5 microns. The instrument is to be built by a consortium of five german institutes (Landessternwarte Heidelberg (LSW), Max Planck Institut for Astronomy (MPIA), Max Planck Institut for Extraterrestric Physics (MPE), Astronomical Institut of the Ruhr-University Bochum (AIRUB) and Fachhochschule for Technics and Design Mannheim (FHTG)). LUCIFER will be one of the first light instruments of the LBT and will be available to the community at the end of 2005. A copy of the instrument for the second LBT mirror follows about one year later.
The paper presents a brief status report of the procured and built
hardware, of the workpackages already carried out and summarizes the ongoing work in progress.
In this paper we present the software development process and history of the LUCIFER (LBT NIR spectroscopic Utility with Camera and Integral- Field Unit for Extragalactic Research) multi-mode near-infrared instrument, which is one of the first light instruments of the LBT on Mt. Graham, Arizona. The software is realised as a distributed system in Java using its remote method invocation service (RMI). We describe the current status of the software and give an overview of the planned computer hardware architecture.
LUCIFER (LBT NIR-Spectroscopic Utility with Camera and Integral-Field Unit for Extragalactic Research) is a NIR spectrograph and imager for the Large Binocular Telescope (LBT) on Mt. Graham, Arizona. It is built by a consortium of five German institutes and will be one of the first light instruments for the LBT. Later, a second copy for the second mirror of the telescope will follow.
Both instruments will be mounted at the bent Gregorian foci of the two individual telescope mirrors. The final design of the instrument is presently in progress.
LUCIFER will work at cryogenic temperature in the wavelength range from 0.9 μm to 2.5 μm. It is equipped with three exchangeable cameras for imaging and spectroscopy: two of them are optimized for seeing-limited conditions, the third camera for the diffraction-limited
case with the LBT adaptive secondary mirror working. The spectral resolution will allow for OH suppression. Up to 33 exchangeable masks will be available for longslit and multi-object spectroscopy (MOS) over the full field of view (FOV). The detector will be a Rockwell HAWAII-2 HgCdTe-array.
In this paper we present the design of the control software for the LBT NIR spectroscopic Utility with Camera and Integral- Field Unit for Extragalactic Research (LUCIFER) which is one of the first-light instruments for the Large Bin-ocular Telescope (LBT) on Mt. Graham, Arizona. The LBT will be equipped with two identical LUCIFER instruments for both mirrors. Furthermore we give an overview of the intended hardware structure of the instrument. Since the project requires a detailed and exact modeling of the software we present UML diagrams starting with an overall model down to use case, activity and class diagrams including an example for one special instrument unit
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.