The vortex flowmeter works in a poor environment,
therefore the stability and accuracy of the online
testing system have become the core question for
getting high accuracy. The optical probe is the main
part of the system which produces and obtains the
vortex signal. This paper designs the vortex shedder
according to the hydromechanics principle, and it is
proposed to be ringlike structures, also gives the test
results which prove the effectiveness of the shedder on
vortex decomposition. A liquid flow online testing
system is designed according to the vortex signal
characteristics, and the optical fiber is chosen as the
sense organ. Then it designed the probe's parameters
and the necessary important circuits of the system to
further increase its accuracy.
It also assembles the sensor system which is
designed to insure the rationality, reliability, stability of
the structure. Finally it proposed the methods on the
coefficient revision and the liquid condition parameter
compensation to get higher accuracy.