Time-resolved (TR) near-infrared spectroscopy (NIRS) offers non-invasive clinical applications in monitoring the blood oxygenation, where absolute values of oxygenated and deoxygenated hemoglobin, and absorption and scattering coefficient, can be obtained. Various detectors have been utilized to realize a TR-NIRS system, such as PMT, SiPM, and SPAD. This paper proposed a prototype NIRS device implemented using a 128 x 128 lock-in pixel CMOS image sensor (CIS) based on the lateral electric field-charge modulator (LEFM) to achieve high time resolution. Preliminary experiments based on the reflectance of an agar phantom with varying absorption coefficient have been conducted and the ability to detect the changes in the absorption coefficient has been demonstrated. The reflectance of the agar phantom is directly observed by the image sensor, which was operated at a time-window of 900 ps with a sensor detection area of 2.9mm2 . The results suggest that a NIRS device using CIS is feasible, which opens the potential of a miniature wearable time-resolved NIRS device.
Terahertz (THz) spectroscopy and imaging of biomedical samples is expected to be an important application of THz analysis techniques. Identification and localization of tumor tissue, imaging of biological samples, and analysis of DNA by THz spectroscopy have been reported. THz time-domain spectroscopy (TDS) is useful for obtaining the refractive index over a broad frequency range. However, THz-TDS spectra of fresh tissue samples are sensitive to procedures such as sample preparation, and a standardized measurement protocol is required. Therefore, in this work, we establish a protocol for measurements of THz spectra of fresh tissue and demonstrate reliable detection of rat brain tumor tissue. We use a reflection THz-TDS system to measure the refractive index spectra of the samples mounted on a quartz plate. The tissue samples were measured immediately after sectioning to avoid sample denaturalization during storage. Special care was taken in THz data processing to eliminate parasitic reflections and reduce noise. The error level in our refractive index measurements was as low as 0.02 in the frequency range 0.8–1.5 THz. With increasing frequency, the refractive index in the tumor and normal regions monotonically decreased, similarly to water, and it was 0.02 higher in the tumor regions. The spectral data suggest that the tumor regions have higher water content. Hematoxylin-eosin stained images showed that increased cell density was also responsible for the observed spectral features. A set of samples from 10 rats showed consistent results. Our results suggest that reliable tumor detection in fresh tissue without pretreatment is possible with THz spectroscopy measurements. THz spectroscopy has the potential to become a real-time in vivo diagnostic method.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.