Paper
12 December 1978 The Effects Of Boresighting Errors When Using Two Mosaic Focal Planes
R. T. Pohlman
Author Affiliations +
Abstract
In many sensor systems, simultaneous sightings with two independent focal planes are required. A two-color experiment is an example. When the sensor has a mosaic focal plane with thousands or millions of detectors, precise alignment between each pair of corresponding detectors is impossible. The individual chips on each focal plane will be offset from the desired position. These offsets can be in two linear directions, a rotation, or a combination of these. The effect of these offsets depends both on the distribution of the energy in the observed scene and on the parameters of the sensor. In this paper, these effects are analyzed. A specific example is shown to demonstrate the effects and method of evaluation. No discussion is included about how to align the focal planes, how to measure the boresight errors, or the sensor rigidity requirements.
© (1978) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
R. T. Pohlman "The Effects Of Boresighting Errors When Using Two Mosaic Focal Planes", Proc. SPIE 0156, Modern Utilization of Infrared Technology IV, (12 December 1978); https://doi.org/10.1117/12.956772
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Error analysis

Spatial frequencies

Infrared technology

Infrared sensors

Signal processing

Statistical analysis

RELATED CONTENT


Back to Top