Serial scan thermal imaging systems require high speed scanning in order to generate a standard TV display of a scene. This is commonly done with a high speed rotating polygon mirror and a lower speed framing mirror. The scanner which is the subject of this paper uses a high speed rotating disc which embodies a circular array of spherical concave reflectors. Framing of the scene is done with an oscillating plane mirror, as with the polygon scanner. Use of the disc as the high speed line scan element allows a more com-pact scanner which runs at lower speed for a given data rate.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
William H. Taylor "Lens Design Considerations For A New Type Optical Scanner", Proc. SPIE 0554, 1985 International Lens Design Conference, (14 February 1986); https://doi.org/10.1117/12.949275
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

Sensors

Monochromatic aberrations

Scanners

Lens design

Image segmentation

Reflection

RELATED CONTENT

X ray scanner a new device for rapid mapping...
Proceedings of SPIE (August 31 2000)
Optical Design Of Compact Thermal Scanner
Proceedings of SPIE (January 29 1985)
Criterion of phasing in the presence of segment aberrations
Proceedings of SPIE (February 19 2008)

Back to Top