Abstract
Model Calculations The tissue was modelled by the so called Krogh's cylinders, i.e. blood parallel vessels in a specific distance supply the tissue with oxygen. Oxygen transfer in the tissue takes place due to diffusion only which needs an decrease of oxygen concentration with increasing distance to the vessel. A oxygen diffusion rate of D = 2 10-5 cm /s was used. The rate equations for the population density in the levels of the photosensitizer molecule and in the oxygen molecule were build up. All transition shown in Fig. 1 have been considered with the marked rate constants. The system of coupled differential equations were solved numerically on a personal computer which needed computing time up to 36 hours.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Hans-Jochen Foth "Model calculation on the efficiency of PDT by pulsed laser application", Proc. SPIE 10313, Opto-Canada: SPIE Regional Meeting on Optoelectronics, Photonics, and Imaging, 103132I (29 August 2017); https://doi.org/10.1117/12.2283886