Paper
10 April 1989 High-Power Thyratron-Type Switch For Laser Applications
G. Kirkman, W. Hartmann, T. Y. Hsu, R. L. Liou, M. A. Gundersen, P. Ingwersen, S. S. Merz
Author Affiliations +
Proceedings Volume 1046, Pulse Power for Lasers II; (1989) https://doi.org/10.1117/12.951336
Event: OE/LASE '89, 1989, Los Angeles, CA, United States
Abstract
A review of recent progress in the development of the low-pressure (~27 Pa H2) glow discharge pulsed high-power (10~30kV) switch, the Back-Lighted Thyratron (BLT), is to be presented. The BLT operates with a glow discharge and utilizes a simple device geometry. New data on peak current capability, current rise rate, current reversal ability, life, repetition rate operation, and trigger efficiency and comparisons of delay and jitter with different trigger methods (flash-triggered, laser-triggered and electrically-triggered) are reported.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
G. Kirkman, W. Hartmann, T. Y. Hsu, R. L. Liou, M. A. Gundersen, P. Ingwersen, and S. S. Merz "High-Power Thyratron-Type Switch For Laser Applications", Proc. SPIE 1046, Pulse Power for Lasers II, (10 April 1989); https://doi.org/10.1117/12.951336
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Switches

Electrodes

Excimer lasers

Ultraviolet radiation

Inductance

Laser applications

Pulsed laser operation

RELATED CONTENT

Power and pulse energy scaling for high volume UV laser...
Proceedings of SPIE (February 17 2017)
Excimer Lasers With Large Discharge Cross Section
Proceedings of SPIE (April 26 1989)
Analysis of high-power XeCl excimer laser
Proceedings of SPIE (April 22 1996)
Kilowatt-range high-repetition-rate excimer lasers
Proceedings of SPIE (September 01 1991)

Back to Top