Paper
1 December 1989 On-Line FTIR Measurement Of The DEG-Content In Molten PETP Using A High Pressure, High Temperature Flow Cell.
Ralph K. Stengler, Gerald Weis
Author Affiliations +
Proceedings Volume 1145, 7th Intl Conf on Fourier Transform Spectroscopy; (1989) https://doi.org/10.1117/12.969585
Event: Seventh International Conference on Fourier and Computerized Infrared Spectroscopy, 1989, Fairfax, VA, United States
Abstract
Polyester, especially polyethylene terephthalate (PETP), have a wide range of use, e.g. synthetic fibres and films. They are usually made by polycondensation of ethylene glycol and terephthalic acid. The remaining content of ethylene glycol (in, our case diethylene glycol DEG) gives an important information about the status of the polycondensation, which determines the mechanical properties of the polymer. In order to get detailed information about the PETP quality during the production it is of interest to measure and control the DEG-content in the PETP melt. During the classical preparation of a sample, occasionally there are changes in the chemical composition of the polymer (e.g. a degassing of monomers is possible). Therefore an AUTOMATIK IROS-100 infrared on-line system was used to avoid those errors since this system directly analyzes the polymer melt at the process temperature in a side-stream of the main polymer line. The molten polymer coming from a bypass of the polymer line is conveyed by a pressure controlled gear pump through a specially developed infrared cell. A special preparation of the sample is not needed. It was possible to quantify the DEG-content in PETP, which was in the range of 0.5 % - 3 %, using an infrared absorption peak with a peak location of approx. 3334 cm-1. It could be demonstrated that the moisture content of the PETP did not influence the above mentioned results. The accuracy of this method was better than 0.2 %.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ralph K. Stengler and Gerald Weis "On-Line FTIR Measurement Of The DEG-Content In Molten PETP Using A High Pressure, High Temperature Flow Cell.", Proc. SPIE 1145, 7th Intl Conf on Fourier Transform Spectroscopy, (1 December 1989); https://doi.org/10.1117/12.969585
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Polymers

Infrared radiation

FT-IR spectroscopy

Temperature metrology

Absorption

Chemical analysis

Error analysis

RELATED CONTENT


Back to Top