Presentation + Paper
6 March 2023 A wearable optical sensor monitoring bladder urine volume to aid rehabilitation following spinal cord injury
A. J. Macnab, P. Pourabbassi, N. Hakimi, W. N. M. J. Colier, L. Stothers
Author Affiliations +
Abstract
Background: Spinal cord injury (SCI) compromises bladder function, including the ability to sense the need to void. Overdistension leads to involuntary leakage and endangers health through upper renal tract pressure damage and autonomic dysreflexia. A monitor warning the bladder is full will allow optimal use of manual expression or intermittent catheterization. Methods: The wearable interface is a silicone sheet worn over the bladder, which incorporates a grid of 4 near-infrared LED transmitters with 3 wavelengths (2 at 950 nm for water detection and 2 of 760 and 850 nm for conventional monitoring of O2Hb and HHb). The system has 8 continuous-wave measurement channels and monitors at 2 different vertical levels to detect variation in bladder fullness; IOD’s of 30 and 40mm provide information at 2 depths. Associations between optical densities during bladder emptying and then during natural filling were compared. Results: Data from 4 male and one female subject were analyzed. The optical densities recorded at the lower vertical locations showed positive correlation with the voiding rate (ratio of scale signal), and O2Hb and HHb concentration changes at higher vertical locations revealed muscle activation prior to voiding. Discussion: This pilot study provides proof of the feasibility of using a 950nm wavelength incorporated into a wearable NIRS bladder monitoring system to transcutaneously and non-invasively detect changes in bladder volume in real-time. Conclusions: Ongoing research is warranted to further evaluate the system as the bladder fills naturally; and establish the clinical value of the data obtained to patients living with spinal cord injury
Conference Presentation
© (2023) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. J. Macnab, P. Pourabbassi, N. Hakimi, W. N. M. J. Colier, and L. Stothers "A wearable optical sensor monitoring bladder urine volume to aid rehabilitation following spinal cord injury", Proc. SPIE 12375, Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables IV, 1237508 (6 March 2023); https://doi.org/10.1117/12.2650381
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Bladder

Near infrared spectroscopy

Injuries

Signal attenuation

Transmitters

Chromophores

Spinal cord

Back to Top