7 April 2023 A histotripsy targeting approach using a mobile C-arm
Author Affiliations +
Abstract
Histotripsy is an emerging noninvasive, nonthermal, and nonionizing tumor treatment, which uses focused ultrasound to mechanically destroy tissue. Currently, targeting is performed using ultrasound imaging, which can be operator dependent. Additionally, many tumors cannot be seen or are poorly visualized on ultrasound due to obstructions, patient size, location, or echogenicity. In these cases, energy delivery for histotripsy treatment may still be possible if alternative targeting techniques are available. In this study, a mobile C-arm based targeting approach is presented, where a tumor can be selected on a 3D cone beam CT (CBCT) and automatically targeted using a histotripsy system with a robotic arm. To this end, a hand-eye calibration technique between a mobile C-arm and robotic arm was developed, where a CBCT and eight 2D x-ray acquisitions of a calibration phantom in different poses were acquired. The phantom poses in the CBCT coordinate system were estimated using a 2D/3D pose estimation approach and the corresponding robot end effector poses in the robot coordinate system were determined from the joint angles. A dual quaternion approach was then used to determine the relationship between C-arm and robot. During treatment, the histotripsy transducer can be aligned on a target using the calibrated robotic arm. Nine dual-modality soft-tissue mimicking phantoms were treated, and the resulting treatment zones were manually segmented from post-treatment CBCTs as reference. The average Euclidean distance between planned and actual treatment centers was 0.81 ± 0.45mm. This approach could considerably increase the number of patients that could benefit from histotripsy treatment, reduce operator dependency, and facilitate clinical translation of histotripsy.
Conference Presentation
© (2023) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Martin G. Wagner, Paul F. Laeseke, Ayca Kutlu, Grace M. Minesinger, Sarvesh Periyasamy, and Michael A. Speidel "A histotripsy targeting approach using a mobile C-arm", Proc. SPIE 12463, Medical Imaging 2023: Physics of Medical Imaging, 124630O (7 April 2023); https://doi.org/10.1117/12.2654002
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Cone beam computed tomography

Robotics

Transducers

Tumors

Ultrasonography

Pose estimation

Back to Top