Paper
1 October 1990 Precise refractive index measurements of infrared materials
Author Affiliations +
Abstract
The precise (five number) infrared refractive index of AMTIR-I glass and chemical vapor deposited zinc selenide were measured over the wavelength range 3-l2pm. The results were temperature corrected and compared to standard values.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Albert Ray Hilton Sr. "Precise refractive index measurements of infrared materials", Proc. SPIE 1307, Electro-Optical Materials for Switches, Coatings, Sensor Optics, and Detectors, (1 October 1990); https://doi.org/10.1117/12.21700
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Prisms

Refractive index

Sensors

Zinc

Electro optical sensors

Electro optics

Glasses

Back to Top