Paper
1 September 1991 Advanced portable four-wavelength NIR analyzer for rapid chemical composition analysis
Author Affiliations +
Proceedings Volume 1510, Chemical and Medical Sensors; (1991) https://doi.org/10.1117/12.47139
Event: ECO4 (The Hague '91), 1991, The Hague, Netherlands
Abstract
This paper discusses the requirements for a portable infrared analyzer and presents the design of a four wavelength NIR analyzer utilizing the integrated multichannel detector technique for wavelength separation and detection. This technique, together with an electrically modulated miniature tungsten filament source and surface mount electronics manufacturing, provides a compact, rugged handheld instrument construction without any moving parts. Improved accuracy and short stabilization time is achieved through a combination of thermoelectric temperature stabilization in the four channel detector and a calculated signal compensation for the residual temperature error. Parallel analog phase sensitive detection of the detector signal maximizes the S/N ratio and maintains the simultaneity of the measurement. All composition calculations are performed in a microcomputer built inside the analyzer. The weight of the prototype analyzer is about 1 kg and a NiCd battery pack provides capacity for hundreds of single measurements or about 3 hours of continuous operation. Two prototype instruments have been fabricated with optimized NIR wavelengths for the moisture measurement of milled fuel peat on production fields. The accuracy of digitized two-wavelength signal ratios were tested in the laboratory over time and against temperature. Full accuracy is achieved in 10 seconds after switch-on and the maximum short time peak-to-peak variation in the signal ratios is 0.2%. The errors due to temperature fluctuations in the range from +2 to +50 degree(s)C are between -0.4 to +0.6%. The instruments were calibrated using 102 samples of Finnish milled fuel peat. the cross-validation testing of calibration gave a standard deviation of 1.6% (moisture by weight) compared to the reference method. Other applications for the analyzer are being planned in wood processing and chemical industries as well as in agriculture.
© (1991) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jouko Malinen and Timo S. Hyvarinen "Advanced portable four-wavelength NIR analyzer for rapid chemical composition analysis", Proc. SPIE 1510, Chemical and Medical Sensors, (1 September 1991); https://doi.org/10.1117/12.47139
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Chemical analysis

Signal detection

Near infrared

Calibration

Lead

Temperature metrology

RELATED CONTENT

Fiber Optic Non-Contact Temperature Probe System
Proceedings of SPIE (April 28 1987)
Time-of-flight application for fluid flow measurement
Proceedings of SPIE (February 20 2009)
Multichannel fiber optic temperature monitor
Proceedings of SPIE (February 07 1994)
Lead salt room-temperature MWIR FPA
Proceedings of SPIE (October 10 2001)

Back to Top