Paper
1 February 1992 Study of LDEF particulate contamination using atomic force microscopy
Mark S. Anderson, Carl R. Maag
Author Affiliations +
Abstract
On the STS-32 Space Shuttle mission, a flight experiment provided an understanding of the effects of the environment on the long duration exposure facility (LDEF) from rendezvous with the shuttle until removal from the payload bay at the Orbiter Processing Facility (OPF) at NASA/KSC. The interim operational contamination monitor (IOCM) is an attached shuttle payload that has been used on two earlier flights (STS 51C and STS 28) to quantify the contamination deposited during the course of the missions. The IOCM can characterize by direct measurement the deposition of molecular and particulate contamination during any phase of flight, i.e., prelaunch, ascent, on-orbit operations, descent, and ferry flight of the shuttle. Measurements are made continually during these periods. Two types of particulate collection sensors are employed in order to avoid efficiency of collection uncertainties. In addition to these principal measurements, the IOCM actively measures the optical property changes of thermal control surfaces by calorimetry, the flux of the ambient atomic oxygen environment, the incident solar flux, and the absolute ambient pressure in the payload bay. The IOCM also provides a structure and sample holders for the exposure of passive material samples to the space environment, e.g., thermal cycling, atomic oxygen, and micrometeoroids and/or orbital debris, etc. One of the more salient results from the STS-32 flight suggests that the LDEF emitted a large source of contamination (mainly particulates) after berthing into the shuttle. The source emission rate of LDEF averaged 2.5 X 10-12 gr/cm2-sec for a period of eighty hours following berthing, falling off to a rate of 4.1 X 10-13 gr/cm2-sec just prior to re-entry. Post flight obscuration ratios on IOCM surfaces were measured at 2.4 percent. An atomic force microscope (AFM) was used to perform post-flight characterization of the IOCM sensors. The AFM is a new instrument capable of ultra high (atomic) resolution without coating the surface or exposing it to vacuum. This paper discusses the results observed by the IOCM during the retrieval of the LDEF, the operational capabilities of AFM, and the unique results acquired in assessing the data.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Mark S. Anderson and Carl R. Maag "Study of LDEF particulate contamination using atomic force microscopy", Proc. SPIE 1556, Scanning Microscopy Instrumentation, (1 February 1992); https://doi.org/10.1117/12.134888
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Contamination

Atomic force microscopy

Crystals

Sensors

Particles

Microscopy

Polymers

RELATED CONTENT


Back to Top