Since the X-ray tubes used in CT scanners produce a polychromatic spectrum, the beam quality changes as the X-ray beam penetrates the scanned object, giving rise to differential beam hardening. Because of this effect, one cannot interpret CT numbers directly in terms of material densities or X-ray attenuation coefficients. Various schemes to correct for the beam hardening effect have been published and are used in commercial scanners. Although computer simulations have demonstrated the potential effectiveness of these schemes, uncertainties in the correction data limit the precision of the results, totally aside from limitations of photon counting statistics. In this work, the most basic beam hardening correction scheme, the water-equivalent correction, is analyzed. A formula is derived which relates uncertainties in the correction data to uncertainties in the reconstructed coefficients. Numerical estimates are given, showing that the uncertainties in the CT numbers can be on the order of 2½% to 10% even with the best correction data available. More sophisticated correction schemes are discussed from the point of reference developed for the water-equivalent correction. The analysis allows one to set requirements on the precision and stability of machine parameters and correction data.
© (1979) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ira J. Kalet "Uncertainties Generated By Computed Tomography (CT) Beam-Hardening Corrections", Proc. SPIE 0173, Application of Optical Instrumentation in Medicine VII, (6 July 1979); https://doi.org/10.1117/12.957150
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Data corrections

Signal attenuation

X-ray computed tomography

X-rays

Bone

Scanners

Error analysis

RELATED CONTENT

Spectral data completion for dual-source x-ray CT
Proceedings of SPIE (March 01 2019)
Sensitometry In Computerized Tomography
Proceedings of SPIE (December 27 1977)
The Role Of CT Scanners In Radiotherapy
Proceedings of SPIE (December 23 1976)
When Is Inhouse Service Cost Effective?
Proceedings of SPIE (August 18 1980)
Optimizing Computed Tomography (CT) Scanner Geometry
Proceedings of SPIE (July 06 1979)

Back to Top