22 April 1993 ATP: continuously variable attenuator for true laser profiles
Author Affiliations +
Proceedings Volume 1834, Laser Energy Distribution Profiles: Measurement and Applications; (1993) https://doi.org/10.1117/12.143863
Event: Applications in Optical Science and Engineering, 1992, Boston, MA, United States
Abstract
Measurement of the beam profile and/or beam width of a laser source is complicated by the fact that most detectors available are just too sensitive. Typical lasers measured in millijoules/cm2 must be attenuated to a few 10s of nanojoules/cm2. To maximize the photoreceptor's digitizer range and operate at a maximum signal-to-noise ratio, it is preferred that the input energy is controlled to just below the detector saturation point. The most common attenuation methods are either discrete in increment, narrow in wavelength range, or operate on a polarization principle that can produce erroneous results for many mixed-mode lasers. Metalized gradient pair attenuators suffer from nonlinear attenuation across the beam and/or multiple interference fringes. What is described here is a novel technique to continuously attenuate an incident laser beam over a ratio of 6300:1 or more (3.8 orders of magnitude). It can be adjusted to the nearest incremental transmission value of 0.005 (0.5 percent). It achieves this at near normal incidence, which is very important if the source contains polarization-dependent laser mode components. Photon, Inc.'s ATP attenuator package achieves this performance without interference fringes, bubbles, or stria and with a minimum of deflection or redirection. A broad wavelength performance also is achieved that ranges from 360 to 2,500-plus nanometers. ATP's primary application is with very sensitive CCD or vidicon array detectors that are capable of measuring beam sizes of a few hundred microns. ATP does this with virtually no root mean square wavefront errors. This device coupled with a high accuracy beam profiler will produce true accurate profiles and beam widths.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
John M. Fleischer "ATP: continuously variable attenuator for true laser profiles", Proc. SPIE 1834, Laser Energy Distribution Profiles: Measurement and Applications, (22 April 1993); https://doi.org/10.1117/12.143863
Lens.org Logo
CITATIONS
Cited by 1 patent.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Attenuators

Acquisition tracking and pointing

Signal attenuation

Absorbance

Glasses

CCD cameras

Laser energy

RELATED CONTENT

Damage effect on CMOS detector irradiated by single-pulse laser
Proceedings of SPIE (September 19 2013)
The design of a laser beam performance test system
Proceedings of SPIE (February 18 2009)
Tips and tricks for aligning an image derotator
Proceedings of SPIE (September 24 2012)
XMM-Newton satellite MOS CCD detectors calibration results
Proceedings of SPIE (November 28 2000)
Precision Broadband Far-Infrared Attenuator
Proceedings of SPIE (September 26 1986)

Back to Top