12 November 1993 Cryogenic cooling program in high heat load optics at the Advanced Photon Source
Carey Shawn Rogers
Author Affiliations +
Abstract
This paper describes some of the aspects of the cryogenic optics program at the Advanced Photon Source (APS). A liquid-nitrogen-cooled, high-vacuum, double crystal monochromator is being fabricated at Argonne National Laboratory (ANL). A pumping system capable of delivering a variable flow rate of up to 10 gallons per minute of pressurized liquid nitrogen and removing 5 kilowatts of x-ray power is also being constructed. This specialized pumping system and monochromator will be used to test the viability of cryogenically cooled, high- heat-load synchrotron optics. It has been determined that heat transfer enhancement will be required for optics used with APS insertion devices. An analysis of a porous-matrix-enhanced monochromator crystal is presented. For the particular case investigated, a heat transfer enhancement factor of 5 to 6 was calculated.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Carey Shawn Rogers "Cryogenic cooling program in high heat load optics at the Advanced Photon Source", Proc. SPIE 1997, High Heat Flux Engineering II, (12 November 1993); https://doi.org/10.1117/12.163804