Paper
8 May 1995 Solid state detector for slit-scan mammography
Bernard Munier, G. Roziere, Jean Chabbal
Author Affiliations +
Abstract
The presentation concerns evaluations that were made to demonstrate the feasibility of a solid state detector intended to produce digital images in slit scan mammography equipment. The detector designed for this modality consists of a multilinear array of x ray sensitive elements. It operates in time delay integration mode. A CsI phosphor screen is directly coupled to a TDI CCD circuit. Typical cell size is 50 micrometers X 50 micrometers . The typical number of lines in the TDI direction is 200. The image format is 4800 X 6000 for a 24 cm X 30 cm field of view. Image acquisition time is 5 seconds. The output signal is converted into a 12 bit coded digital signal. Achievable performance has been demonstrated by performing experiments on a 1024 X 1024 CCD matrix. Cell size is 19 micrometers X 19 micrometers . Cells are electronically binned to achieve a 57 micrometers X 57 micrometers pixel dimension. The matrix is operated in TDI mode along columns, over a 10 mm wide sensitive area. A CsI phosphor layer is applied on the chip surface. Screen density is 65 mg/cm2. The measured conversion efficiency is 190 electrons per absorbed x-ray quantum, 20 keV in energy. The detective quantum efficiency exceeds 50%. The modulation exceeds 10% at a spatial frequency of 8.8 lp/mm (Nyquist frequency of the experimental device). Experiments were conducted to estimate the performance of a Gd202S-based detector. The conclusion is that Gd202S is prohibited in such a detector structure. The major limitation lies in the noise contribution associated with the direct interaction of x-ray quanta in the silicon itself. This contribution is negligible in the case of a CsI-based detector.
© (1995) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Bernard Munier, G. Roziere, and Jean Chabbal "Solid state detector for slit-scan mammography", Proc. SPIE 2432, Medical Imaging 1995: Physics of Medical Imaging, (8 May 1995); https://doi.org/10.1117/12.208357
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Quantum efficiency

X-rays

Silicon

Modulation

Solid state electronics

Mammography

RELATED CONTENT

The spectral response of the EPIC pn camera onboard XMM...
Proceedings of SPIE (February 03 2004)
Noise in hybrid photodiode array CCD x ray image...
Proceedings of SPIE (April 11 1996)
CUBIC: preflight calibration status
Proceedings of SPIE (September 01 1995)
Can Diagnostic Examinations Be Effectively Modeled?
Proceedings of SPIE (December 27 1977)

Back to Top