Paper
29 October 1981 Limit On Remote Fourier Transform Infrared (FTIR) Detection Of Trace Gases
A. S. Zachor, B. Bartschi, M. Ahmadjian
Author Affiliations +
Proceedings Volume 0289, 1981 Intl Conf on Fourier Transform Infrared Spectroscopy; (1981) https://doi.org/10.1117/12.932172
Event: 1981 International Conference on Fourier Transform Infrared Spectroscopy, 1981, Columbia, United States
Abstract
We studied the capability of a Fourier spectrometer system to remotely detect trace gases in localized clouds, e.g., stationary source effluents. Detection is based on the degree to which the observed IR spectral radiance contrast between the cloud and adjacent background is correlated with a computed reference spectrum. It is shown that trace gases can be reliably detected when spectral features are well below the noise level. The minimum detectable quantities (MDQ's) for various trace gases at one atmosphere total pressure are given. The MDQ's determine the combinations of gas column thickness and gas-background temperature difference that correspond to 95 percent detection probability and one percent false detection probability when an FTS system with modest-size foreoptics views the target through a path equivalent to approximately one air mass.
© (1981) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. S. Zachor, B. Bartschi, and M. Ahmadjian "Limit On Remote Fourier Transform Infrared (FTIR) Detection Of Trace Gases", Proc. SPIE 0289, 1981 Intl Conf on Fourier Transform Infrared Spectroscopy, (29 October 1981); https://doi.org/10.1117/12.932172
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Target detection

Gases

FT-IR spectroscopy

Clouds

Atmospheric sensing

Fourier transforms

Sensors