Paper
21 August 1998 Terahertz imaging system based on antenna-coupled microbolometers
Arttu R.M. Luukanen, Veli-Pekka Viitanen
Author Affiliations +
Abstract
In the paper a novel passive submillimeter imaging system is presented. The operation is based on antenna-coupled microbolometer technology operating at room temperature. The demonstration system uses single pixel detector placed in the focus of a 60 cm diameter aluminum parabolic reflector. The primary mirror is tilted about its axis to scan an image at the target plane. The design bandwidth of bolometer spiral antenna is nominally from 300 micrometer (1 THz) upwards. The electrical noise equivalent power (NEP) is exceptionally low 1.5 (DOT) 10-11 W/(root)Hz. Results presented in the paper indicate that the sensor technology is a possible solution in the future to produce large format imaging focal plane arrays for passive terahertz imaging.
© (1998) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Arttu R.M. Luukanen and Veli-Pekka Viitanen "Terahertz imaging system based on antenna-coupled microbolometers", Proc. SPIE 3378, Passive Millimeter-Wave Imaging Technology II, (21 August 1998); https://doi.org/10.1117/12.319403
Lens.org Logo
CITATIONS
Cited by 10 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Antennas

Sensors

Bolometers

Microbolometers

Niobium

Resistance

Silicon