Abstract
Carbon dioxide laser surgery has been limited to a great extent to surgical application on the integument and accessible cavities such as the cervix, vagina, oral cavities, etc. This limitation has been due to the rigid delivery systems available to all carbon dioxide lasers. Articulating arms (series of hollow tubes connected by articulating mirrors) have provided an effective means of delivery of laser energy to the patient as long as the lesion was within the direct line of sight. Even direct line-of-sight applications were restricted to physical dimension of the articulating arm or associated hand probes, manipulators and hollow tubes. The many attempts at providing straight endoscopic systems to the laser only stressed the need for a fiber optic capable of carrying the carbon dioxide laser wavelength. Rectangular and circular hollow metal waveguides, hollow dielectric waveguides have proven ineffective to the stringent requirements of a flexible surgical delivery system. One large diameter (1 cm) fiber optic delivery system, incorporates a toxic thalliumAbased fiber optic material. The device is an effective alternative to an articulating arm for external or conventional laser surgery, but is too large and stiff to use as a flexible endoscopic tool. The author describes the first highly flexible inexpensive series of fiber optic systems suitable for either conventional or endoscopic carbon dioxide laser surgery. One system (IRFLEX 3) has been manufactured by Medlase, Inc. for surgical uses capable of delivering 2000w, 100 mJ pulsed energy and 15w continuous wave. The system diameter is 0.035 inches in diameter. Surgically suitable fibers as small as 120 um have been manufactured. Other fibers (IRFLEX 142,447) have a variety of transmission characteristics, bend radii, etc.
© (1982) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Terry A. Fuller "Carbon Dioxide Laser Fiber Optics In Endoscopy", Proc. SPIE 0357, Lasers in Medicine and Surgery, (28 December 1982); https://doi.org/10.1117/12.976065
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Carbon dioxide lasers

Laser therapeutics

Fiber optics

Endoscopy

Surgery

Waveguides

Laser development

RELATED CONTENT

Contact laser surgery in laryngeal tumor management
Proceedings of SPIE (February 15 1994)
Laser technique in management of laryngomalacia
Proceedings of SPIE (July 01 1998)
Surgical CO2 Laser Units With Specialized Beam-Delivery Systems
Proceedings of SPIE (September 11 1989)
The clinical application of laser in otorhinolaryngology
Proceedings of SPIE (September 11 2006)
Hollow alumina fibers for CO2 laser delivery systems
Proceedings of SPIE (May 01 1990)
Surgical management of laryngomalacia: update 2000
Proceedings of SPIE (May 17 2000)

Back to Top