22 October 1999 Measurement and modeling of the detector response of the pn-EPIC aboard XMM
Martin Popp, Frank Haberl, Ulrich G. Briel, Heike Soltau, Lothar Strueder
Author Affiliations +
Abstract
The pn-EPIC system flight module of XMM was calibrated using the IAS synchrotron facility at Orsay, France. Based on this measurements, a model for the energy response of the pn-CCD was fitted to the data. Only one of the fitted parameters shows significant spatial dependence, while the others only depend on energy. Based on the interpolated parameters, the detector response matrix has been calculated using the partial event model. The validity of this matrix has been tested on existing calibration data. The detector response matrix will be used to analyze spectral observation data taken with pn-EPIC on XMM.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Martin Popp, Frank Haberl, Ulrich G. Briel, Heike Soltau, and Lothar Strueder "Measurement and modeling of the detector response of the pn-EPIC aboard XMM", Proc. SPIE 3765, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy X, (22 October 1999); https://doi.org/10.1117/12.366551
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Data modeling

Calibration

Absorption

Charge-coupled devices

Silicon

X-rays

RELATED CONTENT

X-ray CCD calibration for the AXAF CCD Imaging Spectrometer
Proceedings of SPIE (November 19 1998)
X-ray CCD calibration for the AXAF CCD Imaging Spectrometer
Proceedings of SPIE (October 31 1996)
CUBIC: preflight calibration status
Proceedings of SPIE (September 01 1995)
Calibration of the UV ion shields for the AXAF High...
Proceedings of SPIE (October 15 1997)
Flight spectral response of the ACIS instrument
Proceedings of SPIE (March 11 2003)

Back to Top