Paper
19 January 2001 Comparison of adhesive markers, anatomical landmarks, and surface matching in patient-to-image registration for frameless stereotaxy
Peter W. A. Willems, Jan Willem Berkelbach van der Sprenkel, Cees A. F. Tulleken M.D.
Author Affiliations +
Abstract
The application accuracy of frameless stereotaxy depends partly on the accuracy of the patient-to-image registration procedure. We compared the application accuracy of registration procedures based on anatomical landmarks, surface matching, and adhesive markers. After acquisition of a 3D-MRI volume, 30 patients were subjected to all three registration procedures. Frameless stereotaxy was performed with the STN system (Carl Zeiss, Germany). Following each registration procedure, the root-mean-squared-error (RMSE) and the target registration error (TRE) of an extra adhesive marker (target) were recorded. The first represents the goodness-of-fit of the registration procedure (not available in surface matching) while the second represents the application accuracy. The mean TRE+/- SD for each type of registration was 5.3+/- 2.1mm, 9.4+/- 6.6mm, and 3.6+/- 1.6mm (paired t-tests: p<0.01). When anatomical landmarks were used, anterior targets generated smaller TREs than posterior targets (4.6+/- 2.0mm and 6.8+/- 1.3mm respectively, t-test: p<0.01). There was no significant correlation between the RMSE and the TRE (anatomical landmarks: R2=0.071, adhesive markers: R2=0.004). A more detailed evaluation of surface matching, using a plastic skull phantom, also could not demonstrate an improvement in application accuracy due to surface matching. In conclusion, our results indicate that adhesive markers offer the most accurate alternative to bonescrews. However, we believe anatomical landmarks to provide sufficient accuracy for many neurosurgical procedures concerning frontally located targets, reducing the need for extra preoperative imaging.
© (2001) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Peter W. A. Willems, Jan Willem Berkelbach van der Sprenkel, and Cees A. F. Tulleken M.D. "Comparison of adhesive markers, anatomical landmarks, and surface matching in patient-to-image registration for frameless stereotaxy", Proc. SPIE 4158, Biomonitoring and Endoscopy Technologies, (19 January 2001); https://doi.org/10.1117/12.413791
Lens.org Logo
CITATIONS
Cited by 9 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Adhesives

Image registration

Head

Microscopes

Skull

Computed tomography

Distance measurement

Back to Top